ClinicalTrials.Veeva

Menu

Clip Placement Following Colonic Endoscopic Mucosal Resection (EMR) (CLIPPER)

R

Radboud University Medical Center

Status

Completed

Conditions

Polyp, Colonic
Bleeding

Treatments

Device: Olympus Quick Clip Pro - Single Use Repositionable Clips

Study type

Interventional

Funder types

Other

Identifiers

NCT03309683
R0003871

Details and patient eligibility

About

Study design: A national, multi-center, patient-blinded, randomized clinical trial.

Study population: Patients undergoing EMR with a moderate to severe risk (right sided colon, ≥2cm) of developing Delayed Bleeding (DB).

Intervention: PC will be compared to standard care (no PC).

Main study endpoints: Primary endpoint is the incidence of DB. Secondary endpoints are cost-effectiveness, quality of life and (severe) adverse events related to PC, adenoma recurrence and risk factors for DB.

Full description

Design

This is a multi-center, randomized, patient-blinded multicenter trial, comparing two treatment strategies in 356 patients undergoing EMR for a colonic lesion 2-6 cm. The study will be enrolled in a selection of academic and non-academic Dutch hospitals. Patients undergoing an EMR will be a randomly allocated by web-based randomization to:

A) PC treatment group: minimally 1 clip per 1 cm of the polyp resection plane: OR B) Control group: standard care: only clip placement in case of uncontrollable bleeding (not successfully managed by coagulation) AND/OR perforation.

Population The target population in this proposal includes patients of 18 years and older, who gave written informed consent, undergoing EMR of a colonic polyp with a moderate to severe risk of developing DB. Moderate-severe risk of DB is defined as a laterally spreading or sessile polyp morphology proximal to the splenic flexure, measuring 2-6cm. Given the significantly increased risk of bleeding in the cecum, ascending and transverse colon, clip placement at this location may have the greatest benefit.

Inclusion Gastroenterologists from participating hospitals of the Dutch EMR Study Group will be asked to recruit patients for the trial. They will provide written information about the trial to potential participants, i.e., all patients scheduled for an EMR of a (right-sided) colonic polyp 2-6 cm, and 18 years or older. Members of the study group will contact potentially eligible patients at the outpatient clinic, hospital wards or by phone and give detailed information about the trial. In- and exclusion criteria will be checked and questions about the trial will be answered. Eligible patients will be invited to participate. After both the patient and the study physician or nurse practitioner have signed the informed consent form, in- and exclusion criteria will be checked again and baseline measurements will be performed, which include disease specific questionnaires including risk-factors for DB (AC use, restarting AC, polyp size, visible vessel, etc) and generic and disease specific quality of life questionnaires (see below). Patient's contact details will be provided to the study center for randomization.

Standard of care (usual care) In Dutch common practice, PC is not standard of care. PC is used, based on the personal preference of the endoscopist, mostly in case of intra-procedural bleeding/(possible)perforation. In our study group the minority of endoscopists applies PC after EMR in case of high risk patients, defined as right-sided flat polyps of at least 2cm and on AC or AP therapy.

Definition clinical significant delayed bleeding (DB)

DB is defined as any bleeding occurring after the completion of the procedure necessitating blood transfusion, hospitalization, or re-intervention (either repeat endoscopy, angiography, or surgery). Self-limiting bleeding managed on an outpatient basis is not included. Severity of DB Severity of bleeding is defined according to the ASGE working party document for adverse events in colonoscopy:

  1. Mild DB: any post-EMR medical consultation, unplanned hospital admission, or prolongation of hospital stays for 3 days or fewer.
  2. Moderate DB: unplanned hospital admission of 4 to 10 days, transfusion, repeat endoscopy, any interventional radiology procedure, or intensive care unit (ICU) admission for 1 night.
  3. Severe DB: admission to the ICU for more than 1 night, unplanned admission for more than 10 nights, surgery, or permanent disability.

Treatment of DB DB is primarily treated by resuscitation. In case of resuscitation failure, colonoscopy, angiography with coiling and eventually surgery may be applied to control the bleeding site.

Follow-up After the EMR patients are contacted at 30, 90 and 180 days (short-term and long-term effects). At 180 days a colonoscopy is scheduled to access the adenoma recurrence rate (standard of care).

Enrollment

356 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • laterally spreading or sessile polyp morphology (Paris classification 0-IIa/b/c) proximal to the splenic flexure, measuring 2-6 cm
  • All patients aged >18 years undergoing an EMR
  • Written informed consent

Exclusion criteria

  • Previous resection or attempted resection of a lesion less than 30 days ago or in the same session,
  • Clip deployed prior to the completion of the EMR for a perforation or a major intra-procedural bleeding not treatable by coagulation,
  • Endoscopic appearance of invasive malignancy (non-lifting Kato D, Kudo V pit pattern),
  • Pregnancy,
  • Active inflammatory colonic conditions (e.g. inflammatory bowel disease),
  • Insufficiently corrected anticoagulants AND/OR a clotting disorder (platelet count <50x109/l, INR > 1,5),
  • American Society of Anesthesiology (ASA) Grade IV-V,
  • Macroscopic non-radical resection,
  • >1 lesion in 1 session,
  • Involvement of valvula Bauhin or appendiceal orificium

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

356 participants in 2 patient groups

Clip group
Experimental group
Description:
Olympus Quick Clip Pro - Single Use Repositionable Clips will be used for Prophylactic clipping after EMR
Treatment:
Device: Olympus Quick Clip Pro - Single Use Repositionable Clips
Control group
No Intervention group
Description:
Standard treatment after EMR (as described in the detailed study description above)

Trial contacts and locations

2

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems