Closed-loop Anaesthesia for Liver Transplantation: a Pilot Study (THConcentr)

H

Hopital Foch

Status

Completed

Conditions

Liver Transplant
Anesthesia

Treatments

Device: Automated titration of propofol and remifentanil

Study type

Interventional

Funder types

Other

Identifiers

NCT03357900
2009-A00363-54 (Other Identifier)
2009/09

Details and patient eligibility

About

Automated titration of propofol and remifentanil guided by the bispectral index (BIS) has been used for numerous surgical procedures. Orthotopic liver transplantation (OLT) uniquely combines major volaemic changes, an anhepatic phase, and ischaemia-reperfusion syndrome. We assessed the behaviour of this automated controller during OLT

Enrollment

12 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Patients scheduled for OLT

Exclusion criteria

age younger than 18 years, pregnancy, allergy or hypersensitivity to propofol or remifentanil, a medical history of psychiatric illness, and supraspinal neurological disorders

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

12 participants in 1 patient group

Orthotopic liver transplantation
Experimental group
Treatment:
Device: Automated titration of propofol and remifentanil