ClinicalTrials.Veeva

Menu

Closed-loop in Adults With T2D Not Requiring Dialysis (AP-Renal)

U

University of Cambridge

Status

Completed

Conditions

Type 2 Diabetes

Treatments

Other: Multiple Daily Insulin Injections (Control)
Device: CamAPS HX Closed-loop

Study type

Interventional

Funder types

Other

Identifiers

NCT04701424
RG97920

Details and patient eligibility

About

The main objective of this study is to determine the efficacy, safety and utility of fully automated closed-loop glucose control in the home setting over an 8 week period in adults with type 2 diabetes (T2D). This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in adults with type 1 diabetes in the home setting, and in adults with type 2 diabetes in the inpatient setting.

This is an open-label, single centre, randomised, cross-over study, involving two home study periods during which glucose levels will be controlled either by a fully automated closed-loop system or by participants' usual insulin therapy in random order. Each treatment arm is 8 weeks long with a 2-4 week washout period between treatments. A total of up to 30 participants with T2D will be recruited through outpatient clinics to allow for 24 completed participants available for assessment.

Participants will receive appropriate training by the research team on the safe use of the study devices (insulin pump and continuous glucose monitoring (CGM) and closed-loop insulin delivery system). Participants in the control arm will continue with standard therapy and will wear a blinded CGM system.

The primary outcome is time spent with glucose levels in the target range between 3.9 and 10.0 mmol/L as recorded by CGM. Secondary outcomes are the time spent with glucose levels above and below target, as recorded by CGM, and other CGM-based metrics in addition to insulin requirements. Safety evaluation comprises the tabulation of severe hypoglycaemic episodes.

Enrollment

30 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Age 18 years or over
  2. Diagnosis of type 2 diabetes using standard diagnostic practice
  3. Current treatment with subcutaneous insulin
  4. Screening HbA1c ≤ 11% (97mmol/mol) on analysis from local laboratory
  5. Subject is willing to perform regular finger-prick blood glucose monitoring
  6. Willingness to wear study devices
  7. Literate in English

Exclusion criteria

  1. Physical or psychological condition likely to interfere with the normal conduct of the study and interpretation of the study results as judged by the investigator
  2. Known or suspected allergy to insulin
  3. Lack of reliable telephone facility for contact
  4. Pregnancy, planned pregnancy, or breast feeding
  5. Severe visual impairment
  6. Severe hearing impairment
  7. Medically documented allergy towards the adhesive (glue) of plasters
  8. Serious skin diseases located at places of the body, which potentially are possible to be used for localisation of the glucose sensor
  9. Illicit drugs abuse
  10. Prescription drugs abuse
  11. Alcohol abuse

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

30 participants in 2 patient groups

Closed loop insulin delivery
Experimental group
Description:
Unsupervised home use of day and night fully automated closed loop insulin delivery system (CamAPS HX) for 8 weeks The CamAPS HX closed-loop system comprises: Dana insulin pump (Diabecare, Sooil, Seoul, South Korea) Dexcom G6 real-time CGM sensor (Dexcom, Northridge, CA, USA) An Android smartphone hosting CamAPS HX Application with the Cambridge model predictive control algorithm and communicating wirelessly with the insulin pump Glooko/Diasend cloud upload system to monitor CGM/insulin data
Treatment:
Device: CamAPS HX Closed-loop
Standard therapy
Active Comparator group
Description:
Participants in the control arm will continue to follow their current diabetes management plan for the 8 week study period. Participants will be wear a masked continuous glucose monitoring (CGM) system during the 8 week study period
Treatment:
Other: Multiple Daily Insulin Injections (Control)

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems