ClinicalTrials.Veeva

Menu

Combined Nipple Stimulation and Foley Balloon for Cervical Ripening

W

Western Galilee Hospital-Nahariya

Status

Not yet enrolling

Conditions

Cervical Ripening
Induction of Labor

Treatments

Procedure: Mechanical cervical ripening with Foley catheter
Procedure: Foley balloon catheter with nipple stimulation

Study type

Interventional

Funder types

Other

Identifiers

NCT07317674
NHR-0186-25

Details and patient eligibility

About

Labor induction rates have increased substantially worldwide, and successful cervical ripening remains a key determinant of induction outcomes. Mechanical cervical ripening with a Foley balloon catheter is widely used and considered safe, while nipple stimulation promotes endogenous oxytocin release and represents a physiologic method for stimulating uterine contractions. However, the combined effect of nipple stimulation and balloon catheter use has not been systematically evaluated.

This prospective, randomized, double-blinded controlled trial will assess whether the addition of nipple stimulation to Foley balloon catheter cervical ripening improves Bishop score and shortens the induction-to-delivery interval compared with balloon catheter alone. Term pregnant patients (37-42 weeks' gestation) with a singleton, cephalic pregnancy and an unfavorable cervix (Bishop score <6) requiring labor induction will be randomized to receive either Foley balloon catheter plus standardized nipple stimulation or Foley balloon catheter alone.

The primary outcomes are change in Bishop score after catheter removal and time from catheter insertion to delivery. Secondary outcomes include need for additional induction methods, mode of delivery, maternal and neonatal outcomes, pain, patient satisfaction, and breastfeeding rates. The study aims to evaluate the efficacy and safety of incorporating a physiologic intervention into standard mechanical cervical ripening.

Full description

Rates of labor induction have increased substantially in recent decades in Israel and worldwide. Cervical ripening is a critical component of successful labor induction, and an unfavorable cervix, as reflected by a low Bishop score, is associated with prolonged induction, increased need for additional interventions, and higher rates of operative delivery. Mechanical methods, particularly the Foley balloon catheter, are commonly used for cervical ripening due to their effectiveness and favorable safety profile, including a lower risk of uterine tachysystole compared with pharmacologic agents.

Nipple stimulation is a non-pharmacologic, physiologic method that promotes endogenous oxytocin release and uterine contractions, mimicking spontaneous labor. Prior studies have suggested that nipple stimulation may reduce the need for exogenous oxytocin and lower the incidence of uterine hyperstimulation, while achieving comparable maternal and neonatal outcomes. However, the combined use of nipple stimulation with mechanical cervical ripening has not been systematically evaluated.

This study is a prospective, randomized, double-blinded controlled trial designed to evaluate whether the addition of nipple stimulation to Foley balloon catheter cervical ripening improves cervical readiness and shortens the induction-to-delivery interval compared with Foley balloon catheter alone. Eligible participants are term pregnant patients (37-42 weeks' gestation) with singleton, cephalic pregnancies, intact membranes, and an unfavorable cervix (Bishop score <6) who require labor induction for standard obstetric indications.

Participants will be randomized in a 1:1 ratio to one of two study groups. The intervention group will undergo cervical ripening with a Foley balloon catheter in combination with a standardized nipple stimulation protocol using a breast pump. Nipple stimulation will begin one hour after catheter insertion and will consist of alternating stimulation of each breast for 15 minutes with 15-minute rest intervals, for up to six hours, at the maximum tolerable intensity. The control group will receive cervical ripening with a Foley balloon catheter alone, with standard obstetric management.

Fetal heart rate monitoring will be performed at regular intervals according to institutional protocols, with increased monitoring as clinically indicated. The balloon catheter will be removed after 12 hours, earlier if spontaneous labor ensues, membranes rupture, uterine tachysystole occurs, or non-reassuring fetal status is suspected.

Primary outcomes include the change in Bishop score following catheter removal and the induction-to-delivery interval. Secondary outcomes include the need for additional induction methods (e.g., oxytocin or prostaglandins), time to active labor, mode of delivery, maternal complications (including intrapartum fever, chorioamnionitis, postpartum hemorrhage, and uterine tachysystole), neonatal outcomes (Apgar scores, umbilical cord pH, NICU admission), maternal pain and satisfaction scores, and breastfeeding rates.

The findings of this study will provide evidence regarding the efficacy and safety of integrating a physiologic intervention with mechanical cervical ripening and may inform future strategies to optimize labor induction while minimizing pharmacologic exposure.

Enrollment

100 estimated patients

Sex

Female

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Pregnant individuals aged ≥18 years
  • Singleton pregnancy
  • Term gestation (37-42 weeks)
  • Cephalic fetal presentation
  • Intact membranes
  • Bishop score <6 at enrollment
  • Medical indication for labor induction

Exclusion criteria

  • Multiple gestation
  • Previous cesarean delivery or uterine surgery
  • Contraindication to vaginal delivery
  • Major fetal anomalies
  • Active labor at enrollment
  • Unstable fetal lie or presentation
  • Contraindication to Foley balloon catheter insertion
  • Conditions precluding nipple stimulation (e.g., local breast infection, prior breast surgery involving the nipple)

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

100 participants in 2 patient groups

Foley Balloon Catheter Combined With Nipple Stimulation
Experimental group
Description:
Participants in this arm will undergo cervical ripening using a single-balloon Foley catheter. One hour after catheter insertion, nipple stimulation will be initiated using a breast pump according to a standardized protocol (15 minutes per breast, alternating with 15-minute rest periods, for up to 6 hours or until active labor, membrane rupture, uterine tachysystole, or non-reassuring fetal heart rate occurs).
Treatment:
Procedure: Foley balloon catheter with nipple stimulation
Foley Balloon Catheter Alone
Active Comparator group
Description:
Participants in this arm will undergo cervical ripening using a single-balloon Foley catheter alone, without nipple stimulation. Labor management following catheter insertion and removal will follow standard institutional protocols.
Treatment:
Procedure: Mechanical cervical ripening with Foley catheter

Trial contacts and locations

0

Loading...

Central trial contact

Maya Frank Wolf Frank Wolf, Prof.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems