ClinicalTrials.Veeva

Menu

Combined Tactile and Proprioception Training After Spinal Cord Injury

U

University of Manitoba

Status

Completed

Conditions

Spinal Cord Injury

Treatments

Device: Cycling and Mechanical stimulation

Study type

Interventional

Funder types

Other

Identifiers

NCT02554058
Bannatyne2010:157

Details and patient eligibility

About

A novel rehabilitation bike has been developed for patients with incomplete spinal cord injuries that incorporates mechanical stimulators on the bike pedals to stimulate the sensory receptors in the soles of the feet; the effect of mechanical stimulator on muscle strengthening has been reported by NASA to improve muscle atrophy in astronauts in zero-gravity environments. Cycling also stimulates lower limb position sensors. We predict that the combination of mechanical stimulation with cycling may be similar enough to walking over ground to lead to gains in balance and mobility. The present study will evaluate the therapeutic effect of this bike on balance, walking, as well as cortical-spinal and spinal pathways in patients with incomplete spinal cord injuries.

Full description

INTRODUCTION:

Individuals with spinal cord injuries (SCI) experience balance impairments and limitations in walking. Newer research demonstrates that even after several years individuals with incomplete SCIs can make significant gains in function when they are engaged in targeted physical activity. Previous studies using functional electrical stimulation and locomotion training report reduced spasticity and reflex control, increased electromyography activity during stepping, and increased thigh muscles mass. However, these methods and instruments are bulky, expensive, need technical maintenance, and must be used in a clinical setting. A novel rehabilitation bicycle that uses simultaneous stimulation of plantar mechanoreceptors and hip joint proprioceptors was developed in the department of Biomedical Engineering of University of Manitoba. An advantage of this device is that patients can use it at home and with minimal assistance. Five patients completed initial pilot testing and exhibited an overall improvement on the Berg Balance Scale. Presently, the effect of rehabilitation bike training on the plasticity of the spinal and corticospinal neuronal circuitry and consequently its effects on the functional walking capacity are unclear.

OBJECTIVES:

The purpose of the present study is to evaluate the effect of the rehabilitation bike on corticospinal and spinal plasticity, and functional walking and balance in incomplete SCI individuals.

METHODS:

Ten individuals with chronic incomplete SCI will participate in this study. The protocol will include 30 minute training sessions, three times/week, for 8 weeks. The study design will be a before-after clinical trial with two baseline assessments prior to training. Post-training evaluation after two weeks will be done and there will be a post-training follow-up assessment after two weeks.

Evaluations of functional recovery and independence include: Six -Minute and Ten-Meter Walk Tests, Walking index for spinal cord injury(WISCI II). The Berg Balance Scale(BBS) will be conducted to assess balance. Results will be compared before and after training. H-reflex and motor evoked potential (using transcranial magnetic stimulation ,TMS) will also be measured before and after cycling training to assess the plasticity at the level of the spine and in the corticospinal pathways respectively.

ANTICIPATED RESULTS:

Compared to locomotion training with treadmills and robotic devices, using the rehabilitation bike is affordable and patients are able to use it independently at home, without the help of a physical therapist or a caregiver. Results of this study will clarify the possible positive effect of training with the rehabilitation bike on the corticospinal reorganization as well as training effects on the functional recovery of balance and walking. If the findings from the present study are consistent with the initial pilot data, then it will provide incomplete SCI patients and their therapists with a new option for rehabilitation that is feasible and cost-effective. Considering the relatively high incidence of SCI in Manitoba, the findings from this study will directly improve quality of life for Manitobans and Canadians living with spinal cord injuries.

Enrollment

10 patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • The participant should have experienced a traumatic spinal cord injury
  • American Spinal Injury Association (ASIA) class C or D
  • Between 18 and 65 years
  • At least 12 months post- injury to ensure stability of the patient's neurological condition
  • Should be able to walk 10 meters or more with or without assistance (use of braces or walking aids or parallel bars or moderate assistance of one person)
  • Should have range of motion in the lower limb joint sufficient to allow the cycling exercise
  • Discharged from all rehabilitation.

Exclusion criteria

  • Impaired mental capacity
  • Any medical contradiction to cycling training
  • Degenerative spinal disorder
  • Significant diagnosed osteoporosis
  • Excessive spasticity in the legs as measured by a score of more than 3 on the Modified Ashworth Scale or any spasticity that limits the possibility of cycling exercise or walking
  • Obstructive and/or restrictive pulmonary disease
  • Severe spinal and Lower Limb deformities
  • Decubitus ulcer in the area in contact with the bike and bike's bed

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

10 participants in 1 patient group

Cycling and Mechanical stimulation
Experimental group
Description:
Cycling and Mechanical stimulation : 30 minute cycling training, 3 times a week for 8 weeks.
Treatment:
Device: Cycling and Mechanical stimulation

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems