Combined Use of Potassium Nitrate Gel and Diode Laser for Dentin Hypersensitivity (KN-LASER)

U

University of Pavia

Status

Not yet enrolling

Conditions

Dentin Hypersensitivity

Treatments

Device: Diode Laser (Sham)
Device: Diode Laser (Active)
Drug: Potassium Nitrate Gel

Study type

Interventional

Funder types

Other

Identifiers

NCT06967818
2025-KNO3LASER

Details and patient eligibility

About

The aim of this clinical trial is to evaluate the efficacy of the combined use of a diode laser and a potassium nitrate-based desensitizing gel in reducing dentin hypersensitivity in adult patients. Patients who meet the eligibility criteria and for whom informed consent has been obtained will be enrolled and assessed at five timepoints. At baseline (T0), all patients will undergo a professional dental cleaning, collection of medical and dental history, a full periodontal and dental charting, and completion of the Dentine Hypersensitivity Experience Questionnaire (DHEQ) to assess the impact of hypersensitivity on quality of life. Sensitivity will be measured using the Schiff Air Index and the Visual Analog Scale (VAS) in response to air stimulation. At T1, patients will receive the assigned treatment based on randomization. In the test group, the hypersensitive teeth will be treated with topical application of a potassium nitrate gel (Emoform Actisens, 5%) followed by irradiation with a 980 nm diode laser (1.5 W/cm² for 1 minute without contact, then 1 minute with contact and sweeping motion). In the control group, the same potassium nitrate gel will be applied, but the laser will remain inactive (sham laser). Immediately after treatment, the Schiff Air Index and VAS will be reassessed. Follow-up evaluations will be conducted at T2 (1 month after treatment), T3 (3 months), and T4 (6 months). At each follow-up visit, sensitivity will again be measured using the Schiff and VAS indices. At the final follow-up (T4), the DHEQ questionnaire will be administered a second time to assess changes in the patients' perceived impact of dentin hypersensitivity on daily life. Patients are randomized into two groups: Test group: potassium nitrate gel plus active diode laser (980 nm); Control group: potassium nitrate gel plus sham diode laser (inactive). The study aims to determine whether the addition of diode laser irradiation enhances the desensitizing effect of the potassium nitrate gel in both the short and long term (from T1 to T4), as measured by changes in Schiff Air Index, VAS scores, and DHEQ results.

Enrollment

23 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients with good oral hygiene
  • Presence of at least one tooth affected by dentin hypersensitivity
  • Signed informed consent

Exclusion criteria

  • Use of analgesic medication
  • Ongoing orthodontic treatment
  • Non-vital (endodontically treated) teeth
  • Teeth with restorative materials on the surface
  • Pregnant or breastfeeding women

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

23 participants in 2 patient groups

Potassium Nitrate Gel + Active Diode Laser
Experimental group
Description:
Participants receive topical application of a 5% potassium nitrate gel (Emofrom Actisens), followed by treatment with an active 980 nm diode laser (1.5 W/cm² for 1 minute without contact and 1 minute with contact, using a sweeping motion perpendicular to the long axis of the tooth). Sensitivity is measured at baseline (T0), immediately after treatment (T1), and at 1 month (T2), 3 months (T3), and 6 months (T4).
Treatment:
Device: Diode Laser (Active)
Drug: Potassium Nitrate Gel
Potassium Nitrate Gel + Sham Diode Laser
Sham Comparator group
Description:
Participants receive the same topical application of 5% potassium nitrate gel (Emofrom Actisens), followed by treatment with an inactive (sham) 980 nm diode laser using the same procedure and duration as in the active group, but without laser energy. Sensitivity is measured at the same timepoints: baseline (T0), immediately after treatment (T1), 1 month (T2), 3 months (T3), and 6 months (T4).
Treatment:
Device: Diode Laser (Sham)
Drug: Potassium Nitrate Gel