Comparative Effects of Different Noninvasive Ventilation Mode on Neural Respiratory Drive in Recovering AECOPD Patients

G

Guangzhou Medical University

Status

Completed

Conditions

Chronic Obstructive Pulmonary Disease

Treatments

Device: noninvasive positive pressure ventilation

Study type

Interventional

Funder types

Other

Identifiers

NCT01782768
zjianheng

Details and patient eligibility

About

Background: The efficiency of Neural respiratory drive (NRD)expressed by a ratio of ventilation to the diaphragm electromyogram (EMGdi) decreases in patients with COPD .Improving the neural respiratory drive efficiency of COPD will help to relieve the clinical symptom and make the patients feel comfort.Noninvasive positive pressure ventilation(NPPV)is a good treatment to AECOPD patients.It is unknown the effects of different mode of noninvasive positive pressure ventilation(NPPV) such as proportional assist ventilation (PAV) and pressure-support ventilation (PSV) on the efficiency of Neural drive of AECOPD and which mode benefit the patients more.

Objective: To compare the short-term effects of mask pressure support ventilation (PSV) and proportional assist ventilation (PAV) on Neural respiratory drive in recovering patients of AECOPD

Full description

Methods: After the baseline data of spontaneous breathing was collected, 20 hypercapnic recovering AECOPD patients were placed on different mode of noninvasive positive pressure ventilation(NPPV, such as the PAV or PSV mode) randomly. For each mode, three levels (PA-, PA, PA+or PS-, PS, PS+), ) of support were applied.PS and PA are set for the patient's comfort . On the basis of these two levels, 25% increase and reduction assisted level of pressure were set both for PS and PA (PA-, PA+or PS-, PS+). At each level, the patients were ventilated at least 20 minutes until the breathing was stable. The respiratory frequency (RR), tidal volume (VT), transdiaphragmatic pressure (pdi) the pressure-time product (PTP) and root-mean-square(RMS) of EMGdi were calculated. Esophageal and gastric balloon-catheters were used to detect the intra-thoracic and abdominal pressure. Airway pressure was also measured simultaneously. EMGdi was recorded from a multipair esophageal electrode .During ventilation Airflow and ventilation were measured with pneumotachograph.

Enrollment

20 patients

Sex

Male

Ages

50 to 75 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Clinical diagnosis of the COPD (Chronic Obstructive Pulmonary Disease) the COPD patients were all in stable condition during recovery from acute exacerbation.

Exclusion criteria

  • severe Cardiovascular disease
  • Pneumonia
  • neuromuscular and chest wall deformity
  • Respiratory arrest
  • Cardiovascular instability (hypotension, arrhythmias, myocardial infarction)
  • Change in mental status; uncooperative patient
  • High aspiration risk
  • Viscous or copious secretions
  • Recent facial or gastroesophageal surgery
  • Craniofacial trauma
  • Fixed nasopharyngeal abnormalities
  • Burns
  • Extreme obesity

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

Single Blind

20 participants in 1 patient group

Effect of different NPPV mode on NRD
Experimental group
Description:
13 hypercapnic recovering AECOPD patients were placed on different mode of noninvasive positive pressure ventilation(NPPV,such as the PAV or PSV mode) randomly.For each mode, three levels (PA-, PA, PA+or PS-, PS, PS+), ) of support were applied.PS and PA are set for the patient's comfort . On the basis of these two levels, 25% increase and reduction assisted level of pressure were set both for PS and PA (PA-, PA+or PS-, PS+). At each level, the patients were ventilated at least 20 minutes until the breathing was stable.
Treatment:
Device: noninvasive positive pressure ventilation