ClinicalTrials.Veeva

Menu

Comparative Study of Conventional 1.5 and 3.0T MR Images With Synthetically Reconstructed MR Images

General Electric (GE) logo

General Electric (GE)

Status

Completed

Conditions

Clinical Indication for Brain MRI

Treatments

Device: Neurological MRI

Study type

Interventional

Funder types

Industry

Identifiers

NCT02596854
114-2015-GES-0056

Details and patient eligibility

About

This study is being conducted for regulatory submission of the GE Healthcare MAGnetic resonance Image Compilation (MAGiC), a point-of-care synthetic MR reconstruction software for GE 1.5T and 3.0T MR scanners.

Full description

This study is a prospective, blinded, multi-center multi-reader (MCMR) clinical trial that is statistically powered for non-inferiority of diagnostic image quality of synthetic MR versus conventional MR and collection of supporting radiologic findings and morphology data from radiologists that reflect anticipated clinical usage of synthetic MR technology.

The study consists of three parts:

Clinical MR acquisition, synthetic MR post-processing at a GE facility, and blinded image evaluation (BIE) of conventional and synthetic images for each subject.

The study will enroll eligible adult subjects with clinical indications for brain MRI that meet applicable site MR safety criteria and are not pregnant. The study consists of one visit, the subject's MRI scan, without additional follow-up. Results are expected to be representative of expected clinical usage of synthetic MAGiC MR technology in clinical practice.

Enrollment

117 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Subjects must:

  1. Be an adult 18 years of age or older;
  2. Have clinical indication for MRI of the brain according to the site standard of care;
  3. If female of childbearing potential (not surgically sterile or post-menopausal), be determined non-pregnant by a medically qualified investigator or demonstrated non-pregnant by negative urine pregnancy test;
  4. Be able to hear and understand instructions without assistive devices;
  5. Have necessary mental capacity to understand instructions be able to comply with protocol requirements;
  6. Are able and willing to provide written informed consent by signing the informed consent form (ICF).

Exclusion criteria

Subjects will be excluded that:

  1. Were previously enrolled in this evaluation;
  2. Have metallic/conductive or electrically/magnetically active implants or attached medical devices (except for dental devices/fillings, surgical clips, and surgical staples) that could be unsafe for MRI;
  3. Have contraindication(s) to MRI scanning per the routine MR Safety Screening policy of the investigational site;
  4. Have severe trauma or pre-existing pathology that is expected to interfere with normal conduct of MR scanning or complete scanning of the brain;
  5. Have medical condition(s) such as those requiring urgent medical care that, in the opinion of a physician Investigator, would prevent safe participation in the study.

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

117 participants in 1 patient group

Neurological MRI
Experimental group
Description:
Images acquired for post processing with synthetic software. This is a crossover design where all subjects receive the same imaging scan, and comparison is done between the raw conventional scan and post-processed images using the research software.
Treatment:
Device: Neurological MRI

Trial contacts and locations

6

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2024 Veeva Systems