Status and phase
Conditions
Treatments
About
The goal of this study is to compare efficacy and safety of Dorzol 20 mg/mL Eye Drops manufactured by JADRAN-GALENSKI LABORATORIJ d.d. (Croatia) aimed at lowering elevated IOP in patients with ocular hypertension and primary open-angle glaucoma (POAG) versus TRUSOPT 20 MG/ML Eye Drops manufactured by Laboratoires Merck Sharp & Dohme-Chibret, France. The main questions it aims to answer are:
A total of 118 participants were screened and randomized 1:1 to the investigational drug (Dorzol) group or the reference drug (Trusopt) group. 59 patients were recruited in each group.
Researchers compared the investigational drug (Dorzol) group with the reference drug (Trusopt) group to see if the efficacy and safety of the investigational drug and the reference drug in patients with ocular hypertension and primary open-angle glaucoma are equal.
Full description
Study Title:
A randomized, open-label, controlled, comparative study of efficacy and safety of Dorzol eye drops, 20 mg/mL, manufacturer: JADRAN - GALENSKI LABORATORIJ d.d., Croatia, vs. Trusopt® eye drops, 20 mg/mL, manufacturer: Laboratoires Merck Sharp & Dohme-Chibret, France, in patients with primary open-angle glaucoma.
Protocol No. DORZOL-10/2015, version No. 1.0 of 25.10.2015 RCT No. 629 of 07.09.2016 Investigators
Abdulaeva Elmira Abdulaevna (Test facility No.4)
Eryomina Alyona Victorovna (Test facility No.6)
Lisitsyn Alexey Borisovich (Test facility No.7)
Doga Alexander Victorovich (Test facility No.8) Test facilities No.4. State autonomous healthcare institution 'Republican Clinical Ophthalmological Hospital of the Ministry of Health of the Republic of Tatarstan', 420012, Republic of Tatarstan, Kazan, Butlerova St., 14.
No.6. Federal state autonomous institution 'Acad. S.N. Fyodorov Eye Microsurgery Interbranch Science and Technology Complex', Ministry of Health of the Russian Federation, 127486, Moscow, Beskudnikovsky Blvd., 59A.
No.7. State healthcare institution of Yaroslavl region 'Clinical Hospital No. 8', 150030. Yaroslavl, Suzdalskoe Highway, 39.
No.8. Federal state autonomous institution 'Acad. S.N. Fyodorov Eye Microsurgery Interbranch Science and Technology Complex', Ministry of Health of the Russian Federation, 127486, Moscow, Beskudnikovsky Blvd., 59A.
Study period:
First patient enrollment date: 5 April 2017 Study completion date: 1 September 2018 Phase III (a safety and efficacy study)
Study objective:
The study objective was to evaluate the efficacy and safety of Dorzol eye drops, 20 mg/mL, manufacturer: JADRAN - GALENSKI LABORATORIJ d.d., Croatia, designed to reduce elevated intraocular pressure in patients with primary open-angle glaucoma (POAG), vs. Trusopt® eye drops, 20 mg/mL, manufacturer: Laboratoires Merck Sharp & Dohme-Chibret, France.
Study tasks:
Study design:
A multicenter, prospective, open-label, randomized, comparative, controlled, parallel-arm study evaluating the efficacy and safety in patients with a specific disease.
Study subjects: 118 patients (59 subjects in each group) with elevated intraocular pressure induced by primary open-angle glaucoma (POAG), males and females in the age bracket of 18 to 75 years conforming to the inclusion and exclusion criteria.
Patients randomized: 118 Dropouts: 1 Per protocol population: 117 Safety population: 118
Inclusion criteria:
Exclusion criteria:
Test product:
Trade name: Dorzol Active ingredient: dorzolamide Pharmaceutical form: eye drops Dosage: 20 mg/mL Posology and method of administration: Instillation into the conjunctival sac of 1 drop 3 times daily for 12 weeks.
Manufacturer: JADRAN - GALENSKI LABORATORIJ d.d., Croatia
Reference product description and labeling:
Trade name: Trusopt® Active ingredient: dorzolamide Pharmaceutical form: eye drops Dosage: 20 mg/mL Posology and method of administration: 3 times daily Manufacturer: Laboratoires Merck Sharp & Dohme-Chibret, France Study duration: Screening: 7 days. The comparison product treatment lasted for 12 weeks (84±2 days). Follow-up period: 7 days. The overall study duration per patient did not exceed 99±2 days.
The efficacy is established based on analysis of the parameters as follows:
Primary endpoint
• Mean IOP change from baseline.
Secondary endpoints
Statistical analysis Statistical analysis was performed using Statsoft Statistica Professional 13 and Microsoft Excel 2016 software.
The Shapiro-Wilk test was used to evaluate the normality of distribution of quantitative attributes. Parametric tests were used for testing statistical hypotheses for parameters with the normal distribution, whereas nonparametric tests were used for parameters with the variance of the distribution. Student's t-test and Mann-Whitney U test were used for comparing the study groups in terms of quantitative attributes. The comparison of intragroup parameters before and after treatment was performed using the dependent samples t-test or the Wilcoxon test. The intragroup comparisons were also performed using nonparametric repeated measures ANOVA (the Friedman test). Qualitative attributes were analyzed using Pearson's χ2 test or Fisher's exact test (if the attribute incidence rate in at least one subgroup was ≤ 5).
Statistically significant are differences with p-values < 0.05. Efficacy analysis of the comparison products provides for a conclusion on
Noninferiority of the test product Dorzol, eye drops (JADRAN - GALENSKI LABORATORIJ d.d., Croatia) vs. reference product Trusopt®, eye drops (Laboratoires Merck Sharp & Dohme-Chibret, France) by the primary endpoint:
Intergroup efficacy comparisons of the comparison products by the secondary endpoints have also been performed, with statistical significance of intergroup differences evaluated for ITT and PP populations:
ITT
o No statistically significant intergroup differences have been observed regarding the IOP reduction rate to the target level of ≤ 18 mm Hg either in the treatment or control group (p = 0.5727; Pearson's χ2 test), which is indicative of Dorzol noninferiority by this parameter vs. reference product.
o No statistically significant intergroup differences have been observed regarding the IOP reduction rate greater than 20% at visit 5 from baseline at visit 1 pre-dose either in the treatment or control group (p = 0.5661; Pearson's χ2 test), which is indicative of Dorzol noninferiority by this parameter vs. reference product.
o No statistically significant intergroup differences have been observed regarding the IOP reduction rate greater than 30% at visit 5 from baseline at visit 1 pre-dose either in the treatment or control group (p = 0.4524; Pearson's χ2 test), which is indicative of Dorzol noninferiority by this parameter vs. reference product.
PP o No statistically significant intergroup differences have been observed regarding the IOP reduction rate to the target level of ≤ 18 mm Hg either in the treatment or control group (p = 0.5212; Pearson's χ2 test), which is indicative of Dorzol noninferiority by this parameter vs. reference product.
o No statistically significant intergroup differences have been observed regarding the IOP reduction rate greater than 20% at visit 5 from baseline at visit 1 pre-dose either in the treatment or control group (p = 0.6494; Pearson's χ2 test), which is indicative of Dorzol noninferiority by this parameter vs. reference product.
The safety evaluation provided for the conclusions as follows:
Analysis of these AEs is indicative of comparable safety of the test product:
o AE occurrence in the treatment group does not differ reliably from AE occurrence in the control group (p = 0.7058; Pearson's χ2 test).
o AE link to the test product was most characterized as 'probable'; there were no statistically significant intergroup differences by this parameter either (p = 0,073).
Analysis of the patients' laboratory test findings has identified statistically reliable differences by certain parameters (hemoglobin, ESR, AST, ALT, urea, total bilirubin, total protein, urine specific gravity). However, these differences are linked to patients' personality traits.
Thus, based on all criteria specified in the Clinical Trial Protocol, the test product Dorzol and reference product Trusopt® demonstrate close efficacy and safety parameters. There are no statistically significant intergroup differences by any efficacy criteria tested. The efficacy differences between the test and reference product by the primary criterion do not exceed the noninferiority margin of 1.5 mm Hg. The above-stated provides for a conclusion on the test product Dorzol noninferiority vs. reference product Trusopt®.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
118 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal