Comparative Study of the Wear of Uncemented Acetabular Conventional Polyethylene and X3 in Total Hip Replacement, for Stereo-radiographic Analysis (COCYCOX)

C

Caen University Hospital

Status

Unknown

Conditions

Total Hip Arthroplasty

Treatments

Device: radiostereometric analysis (RSA)

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Total hip arthroplasty (THA) is one of the most effective medical procedures. Except for the few early complications (acute infections and dislocations), the patient made a PTH can be assured of a significant improvement in its function and its short-term quality of life. However, clinical studies and records have shown that the lifetime of these implants was limited. The main cause of failure is the "aseptic loosening" influenced by many factors, foremost of which is due to periprosthetic osteolysis debris. This is a major concern for orthopedic surgeons loosening leads, in most cases, the recovery, the importance of osteolysis is a major cause of difficulties and poorer results.

The main objective of the study is to compare, 2 years after the intervention, the penetration of the femoral head in the polyethylene and X3 in the acetabulum in N2VAC® conventional polyethylene.

Enrollment

112 estimated patients

Sex

All

Ages

18 to 70 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patient (18-70 years) with hip disease necessitating the establishment of a total hip replacement

Exclusion criteria

  • Patient aged 71 or more
  • Pregnant woman or wishing to be for the duration of the study
  • Resumption of total hip replacement, or cephalic prosthesis cups
  • Primary or secondary malignant neoplasm of the hip
  • Protected adult patient

Trial design

Primary purpose

Basic Science

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

112 participants in 2 patient groups

acetabular liner in X3 polyethylene
Active Comparator group
Description:
acetabular in X3 polyethylene
Treatment:
Device: radiostereometric analysis (RSA)
acetabular liner in N2VAC® conventional polyethylene
Active Comparator group
Description:
hip replacement with acetabular liner in N2VAC® conventional polyethylene
Treatment:
Device: radiostereometric analysis (RSA)