ClinicalTrials.Veeva

Menu

Compare a New Method and Formula as a Guide for the Intubation of a Left-sided Double-lumen Tube

T

The First Hospital of Qinhuangdao

Status

Completed

Conditions

Therapeutic Procedural Complication

Treatments

Other: Formula
Other: Measurement

Study type

Observational

Funder types

Other

Identifiers

Details and patient eligibility

About

One-lung ventilation (OLV) is required for the most of thoracic surgery to facilitate surgical visualization by collapsing the lung. The double-lumen tube (DLT) is the commonly used device for OLV. The objective of this study was to compare the accuracy of the distances between vocal cords to carina of trachea and formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube

Full description

In previous study, investigators found that the distances between vocal cords to carina of trachea was a useful predictive method for the intubation of a Left-sided Double-lumen tube. However in some hospitals preoperative chest CT scans not contain the vocal cords slice. So in this study investigators will compare the accuracy of the distances between the midpoint of the thyroid cartilage to suprasternal notch base on body surface measurement add the distance between suprasternal notch to carina of trachea according to chest CT and formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube.

Enrollment

60 patients

Sex

All

Ages

18 to 70 years old

Volunteers

Accepts Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria:

  1. Adult patients undergoing elective left side thoracic surgery
  2. Requiring a Uniblocker or DLT for one-lung ventilation

Trial design

60 participants in 2 patient groups

Measurement
Description:
The distances between the midpoint of the thyroid cartilage to suprasternal notch base on body surface measurement add the distance between suprasternal notch to carina of trachea according to chest CT.
Treatment:
Other: Measurement
Formula
Description:
The formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube. The depth of intubation = 0.1977\* height-4.2423
Treatment:
Other: Formula

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems