Status
Conditions
Treatments
About
The aim of this randomized clinical trial was to compare
I- The clinical behavior of implant retained removable overdenture using telescopic retention system fabricated using CAD\CAM techniques where the effects of the different material combinations were examined in regard to:
II - The radiographic behavior regarding marginal bone level and bone density.
Full description
This study compared implant-retained telescopic mandibular overdentures reinforced with milled metal framework (Co-Cr) and milled polymer (PEEK) in terms of retention, periimplant mucosal health, and radiographic changes in twelve patients.
Initially, all patients received conventional complete dentures. A CBCT was conducted prior to the implant surgical phase using a radiographic stent. Two implants were inserted interforaminally using a flapless method. The implants were then left for three months to allow for osseointegration, and the patients were instructed to wear their complete dentures during the healing process.
Following the osseointegration period, the prosthetic phase began, with all patients obtaining primary crowns constructed from titanium alloys. The patients were then randomly divided into two groups, 6 patients in each group. Group A received a COCR framework that included secondary crowns while group B received a PEEK framework and secondary crowns.
Retention was tested for each group (baseline, 6 months, 9 months, and 12 months) using a digital force gauge. The pulling force gradually increased until the denture was dislodged. The retentive force was measured during the initial separation of the telescopic crown.
Soft tissue conditions was assessed using single coded probe for each group (baseline, 6 months, 9 months, and 12 months).Bleeding tendency on probing, plaque accumulation, calculus deposition, perimplant mucosal health were the parameters for each group evaluation.
While the radiographic assessment was performed for each group (baseline, 6months, 9 months and12 months) using digital periapical radiographs by the means of XCP instrument and digital sensor. The marginal bone level was measured by evaluating the difference of bone level at the neck of the implant. The bone density was evaluated at three areas surrounding the implants.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
12 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal