The purpose of this study is determine the agreement of point of care (POC) clotting tests (INR and aPTT) by the POC device by Hemochron Jr versus standard laboratory clotting tests (INR and aPTT) in patients undergoing elective cardiac surgery.

Full description

The study is a correlation between POC Hemochron Jr INR and aPTT with the standard.

Enrollment

20 estimated patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • did not receive anticoagulants or clopidogrel within 5 days preoperatively

Exclusion criteria

  • history of coagulopathy
  • heparin resistance
  • receiving heparin or warfarin
  • hepatic or renal dysfunction
  • pregnancy
  • urgent or emergency cases

Trial design

20 participants in 1 patient group

POC INR and APTT Hemochron
Description:
Adult patients undergoing elective on pump coronary artery bypass grafting surgery who have not received anticoagulants or clopidogrel within 5 days preoperatively.