ClinicalTrials.Veeva

Menu

Comparing the Antibacterial Effect of 810 nm Diode Laser and Photodynamic Therapy

S

Shahid Beheshti University

Status and phase

Unknown
Phase 2

Conditions

Periradicular Disease

Treatments

Drug: Methylene blue
Device: diode laser

Study type

Interventional

Funder types

Other

Identifiers

NCT02555488
shahid beheshti university

Details and patient eligibility

About

The aim of this study was to compare the Antibacterial Efficacy of Diode Laser 810nm and Photodynamic therapy in reducing bacterial microflora in endodontic retreatment of teeth with periradicular lesion.

Full description

Conventional techniques of root canal treatments such as mechanical instrumentation and chemical debridement with antimicrobial irrigants, such as Sodium hypochlorite (NaOCl) and chlorhexidine and use of calcium hydroxide do not always suffice to predictably render root canals free of bacteria Using the high-power diode laser is a new approach of disinfection allowing access to the previously unavailable areas, such as the tubular network. This study, therefore, compares two types of diode lasers (low-power and high power) in terms of anti-bacterial effect as well as the conventional endodontic retreatment to determine the ideal method of root canal disinfection.

Enrollment

20 estimated patients

Sex

All

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • endodontic retreatment of teeth with periradicular lesion.

Exclusion criteria

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

20 participants in 2 patient groups

2
Experimental group
Description:
in the second group diode laser (810 nm, 1.2 W, 30 s) was irradiated. Then second samples were taken from all canals.
Treatment:
Device: diode laser
Device: diode laser
1
Experimental group
Description:
In the first group Photodynamic therapy (PDT) with Methylene blue and diode laser (810 nm, 0.2 W, 40 second) was done
Treatment:
Drug: Methylene blue
Device: diode laser
Device: diode laser

Trial contacts and locations

1

Loading...

Central trial contact

saranaz azari-marhabi, DMD; mohammad asnaashari, DMD

Data sourced from clinicaltrials.gov