Comparing the Safety and Efficacy of Paclitaxel Controlled Release Balloon Catheter (VasoguardTM) in the Treatment of Small Coronary Vessel Stenosis With a Common Coronary Balloon Catheter (Maverick2)

S

Shandong Branden Med.Device

Status and phase

Unknown
Phase 3

Conditions

Small Vessel Lesion

Treatments

Device: common balloon catheter (Maverick2)
Device: paclitaxel controlled release balloon catheter (VasoguardTM)

Study type

Interventional

Funder types

Industry

Identifiers

NCT02891005
Branden-123

Details and patient eligibility

About

Study Purpose The safety and efficacy of paclitaxel controlled release balloon catheter VasoguardTM in treatment of small vessel lesion.

Study Group Experimental group: paclitaxel controlled release balloon catheter (VasoguardTM) Control group: common balloon catheter (Maverick2)

Enrollment

230 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Subject need 18 to 80 years of aged male or non-pregnant women; Subject has stable anina pectoris, or unstable anina pectoris, or old myocardial infarction patients, or ischemia with evidence but without symptom; Subject has a life expectancy of more than 2 years; Lesion vessel reference diameter is less than or equal to 2.5mm, target lesion length is less than or equal to 40mm; Target lesion stenosis is equal or greater than 70% or 50% and with ischemia; Single or two coronary small vessel lesions in situ; Subject can understand the trail purpose, sign informed consent voluntarily, agree to accept clinical telephone follow-up and angiographic follow-up at 9 months; Target lesion can be pre-expanded successfully (Guide wire can get through lesion, balloon pre-expand the remnant stenosis of vessel lumen is less or equal to 50%, without current limiting interlayer and thrombosis).

Exclusion criteria

Patient that in the opinion of the investigator is not appropriate for this trail; Pregnancy and lactation female patients; Patient has a life expectancy of less than 2 years; Severe congestive heart failure or NYHA IV heart failure; Patient who have bleeding constitution, cannot use antithrombotic and antiplatelet drugs; Patient that happened acute myocardial infarction within a week; Patient who happened stroke within six months; Patient who with severe renal failure (GFR≤30ml/Min); Patient has received heart transplantation; Patient who cannot tolerate aspirin and / or P2Y12 receptor inhibitor drugs; Patient who has allergy to paclitaxel, PLGA or contrast agent; Peptic ulcer or gastrointestinal bleeding within the prior 6 months; Patients who are participating in another drug or device clinical trail, which have not completed the primary endpoint follow- up period.

Angiographic relevant: Merge three or more coronary small vessel lesions; Target vessel with extensive thrombosis evidence; Restenosis of vein graft after bypass surgery; Target lesion proximal exist seriously distorted or severe calcified lesion.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

230 participants in 2 patient groups

paclitaxel controlled release balloon catheter
Experimental group
Description:
Patients treated with paclitaxel controlled release balloon catheter
Treatment:
Device: paclitaxel controlled release balloon catheter (VasoguardTM)
common balloon catheter
Experimental group
Description:
Patients treated with common balloon catheter
Treatment:
Device: common balloon catheter (Maverick2)

Trial contacts and locations

1

Loading...

Central trial contact

Yuxia Yin

Data sourced from clinicaltrials.gov