Comparison of Breathing Events Detected by the SleepStyle 200 Auto Continuous Positive Airway Pressure (CPAP) Device to Attended Polysomnography

Fisher & Paykel Healthcare logo

Fisher & Paykel Healthcare

Status

Completed

Conditions

Sleep Apnea, Obstructive

Treatments

Device: SleepStyle 200 Auto Series CPAP Humidifier

Study type

Interventional

Funder types

Industry

Identifiers

NCT00697424
FPHHC254a
AKY/03/07/166

Details and patient eligibility

About

Obstructive Sleep Apnoea (OSA) is a common sleep-breathing disorder affecting around 2-4% of the population and is characterised by loud snoring, periodic collapse of the upper airway particular to sleep, sleep fragmentation, and sometimes daytime sleepiness. Health consequences include impaired cognitive functioning, quality of life, mood, and increased cardiovascular disease risk. Epidemiological studies have demonstrated that increased morbidity and mortality in a dose response manner with increasing severity of sleep disordered breathing.

The standard treatment for OSA is nasal Continuous Positive Airway Pressure (CPAP), which consists of pressurized air applied to the nose via a mask. Generally a single, optimal pressure is prescribed for a patient based on a full night or partial night study during which the pressure is adjusted by a technician until all sleep disordered breathing (SDB) events are abolished. Despite therapy efficacy, compliance to CPAP therapy is sub-optimal.

Due to low compliance it has become common for healthcare providers to follow up subject therapy efficacy through reporting software inherent in many current CPAP devices. Healthcare providers can use this reported data to make appropriate treatment decisions. For this reason the data needs to be accurate. The SleepStyle™ 200 Auto Series CPAP humidifier is an auto adjusting CPAP which stores comprehensive compliance data. The aim of this study is to compare the reliability of the SleepStyle™ 200 Auto Series CPAP data to laboratory-based PSG in detecting sleep disordered breathing.

Hypothesis: The SleepStyle™ 200 Auto Series reporting features accurately detects indices of sleep disordered breathing.

Enrollment

20 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Apnea Hypopnea Index (AHI) >15 from diagnostic night
  • ≥18 years of age

Exclusion criteria

  • Contraindicated for CPAP use

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

1
Experimental group
Description:
All subjects will be placed on continuous positive airway pressure (CPAP) therapy during a full night sleep study or polysomnography (PSG). The subjects will spend 2 hours on sub-therapeutic CPAP 4 cmH2O of pressure and the remainder on there therapeutic pressure. Values reported on the device will be compared to scored values from manual scoring of the sleep study.
Treatment:
Device: SleepStyle 200 Auto Series CPAP Humidifier