Comparison of Change of Tissue Oxygenation During a Vascular Occlusion Test Using Two Different NIRS (O3TM vs. INVOS®)

Seoul National University logo

Seoul National University

Status

Completed

Conditions

Tissue Oxygen Saturation

Treatments

Device: O3

Study type

Interventional

Funder types

Other

Identifiers

NCT03395834
1712-054-905

Details and patient eligibility

About

This study evaluates the change of tissue oxygenation during a vascular occlusion test using two NIRS ( O3TM and INVOS®). NIRS probe will be attached on volunteer's forearm during vascular occlusion test and tissue oxygenation change will be recorded

Full description

Near-infrared spectroscopy (NIRS) has been used to measure regional hemoglobin oxygen saturation of tissue. Recently, it also has been used to monitor peripheral tissue oxygen saturation, and micro-vascular reactivity using vascular occlusion test (VOT).

O3 TM is recently developed NIRS and there are only two clinical trials using this device, until now. In one study, this device could adequately predict cerebral regional oxygen saturation. And in the other study, peripheral tissue oxygenation was measured during ischemic pre-conditioning in heart surgery and it showed correlation between O3 TM and other NIRS ( EQUANOX) which has been used to monitor peripheral tissue oxygenation. But in this study, study group was patient with heart disease and the deoxygenation and reoxygenation rate during VOT was not not measured, which reflects tissue oxygen extraction and micro-vascular reactivity.

In NIRS devices, there are assumed cerebral arterial-venous ratio upon which oximetry values are calculated. In INVOS®, assumed arterial-venous ratio is 25/75. In other NIRS, assumed arterial-venous ratio is 30/70. But unlike other NIRS, O3 TM can change its preset arterial-venous ratio between 25/75 and 30/70, and there are no studies compare oximetry values between these two different settings.

In this study, the investigators try to compare INVOS®, which has been used widely for monitor tissue oxygenation, and two different settings of O3 TM ( arterial-venous ratio; 30/70 and 25/75). Three probes will be attached at same site simultaneously and the investigators will measure change of tissue oxygenation, deoxygenation rate and reoxygenation rate during vascular occlusion test

Enrollment

20 patients

Sex

All

Ages

20 to 60 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Healthy adult without known disease

Exclusion criteria

  • Patients with previously known cardio-vascular disease
  • Patients with body mass index >30kg/m2
  • Patients on vasoactive drug
  • Patients with skin pigmentation on probe attachment site
  • Patients who is pregnant
  • Patients with chronic anemia

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

O3 monitor
Experimental group
Description:
tissue oxygenation comparison of O3 \& INVOS
Treatment:
Device: O3