Status
Conditions
Treatments
About
The aim of the study is to evaluate the accuracy of continuous non-invasive AP monitoring (CNAP) compared to simultaneous IBP measurement in intensive care patients undergoing a transport in the ambulance car.
Since CNAP finger blood pressure is calibrated to NBP level, a systematic bias between IBP and CNAP as described by a recent FDA meta analysis [ ] is expected. The most important factor of CNAP system performance is its ability to accurately track blood pressure changes. Thus, the purpose of this investigation is to show that the bias between CNAP and IBP falls within the expected range and that blood pressure alterations are detected instantaneously.
The endpoints of the study are:
The beat-to-beat readings of CNAP and IBP will be automatically recorded electronically on a memory card in the transport monitor. CNAP data will additionally be recorded directly on the CNAP Monitor with a memory stick. Safety will be assessed by clinical observations as well as adverse events (AE) recording.
Full description
Arterial pressure (AP) is one of the most important physiological variables. Particularly in emergency medicine, AP needs to be monitored repeatedly or even better, continuously. This is usually done using an oscillometric pressure device (NIBP). A number of studies emphasise the importance of continuous AP monitoring as more than 20% of all hypotensive episodes may be missed by NIBP and another 20% are detected with delay. Prolonged hypotension precedes 56% of perioperative cardiac arrests and is associated with a significant increase of the 1-year mortality rate, indicating that NBP monitoring especially in patients with cardiovascular diseases might be insufficient independent from the clinical setting. Recently, a monitor for continuous non-invasive AP monitoring (CNAP™ Monitor 500) was introduced. It was shown that during procedures with high risk of hypotension NIBP missed significant more hypotensive episodes than CNAP. At the moment we have no evidence of the performance of CNAP in the preclinical emergency medicine. The evaluation against the gold standard of invasive pressure measurement in this study will help us to evaluate the performance of CNAP in the preclinical setting.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
40 participants in 1 patient group
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal