ClinicalTrials.Veeva

Menu

Comparison of I-gel to the Laryngeal Mask Airway

The University of Texas System (UT) logo

The University of Texas System (UT)

Status

Completed

Conditions

Supraglottic Airway
Endotracheal Intubation

Treatments

Device: Laryngeal Mask Airway-Unique
Device: i-gel airway (Intersurgical Ltd., Wokingham, England)

Study type

Interventional

Funder types

Other

Identifiers

NCT00706823
HSC-MS-08-0004

Details and patient eligibility

About

The purpose of this study is to evaluate a new disposable supra-glottic airway device, the i-gel airway (Intersurgical Ltd., Wokingham, England). We propose to test its ease of insertion, position within the airway, drain tube patency and anatomic sealing properties during mechanical ventilation in non-obese anesthetized patients undergoing elective general surgery. The study device will be compared to the current standard in the industry, the LMA Unique.

Full description

During the past decade, several pharyngeal airways have been introduced for airway management, such as the Laryngeal Mask Airway (LMA), the Cobra perilaryngeal airway, the Esophageal Tracheal Combitube (ETC), the EasyTube, the Laryngeal Tube6, and the Streamlined Liner of the Pharyngeal Airway (SLIPA). These airway devices have become very popular because of their ability to maintain an airway without perturbing the trachea and can be used in patients without muscle relaxation who are only lightly anesthetized.

The LMA Classic (cLMA) generally provides an adequate airway, but certain problems remain:

  1. In 8-33% of LMA placements, more than one attempt is required.
  2. It is sometimes difficult to advance the LMA without extending the neck (which is contraindicated in some patients).
  3. The device does not protect the airway from aspiration of gastric contents.
  4. It does not provide an airtight seal around the larynx (the usual pressures causing leakage of gas being 15-20 cm H20). Consequently, the device may function poorly during positive-pressure ventilation.
  5. The esophagus is included within the rim of the LMA in 10-15% of patients, directly exposing the esophagus to positive airway pressures. This often results in insufflation of the stomach and postoperative discomfort.

The LMA Unique (uLMA) is a disposable, inflatable supraglottic airway device that is based on the LMA Classic design which has been used as the "model" in the industry. It has been listed as a commonly accepted device for routine and rescue airway management and is now listed in the American Society of Anesthesiologists (ASA) Difficult Airway Management Algorithm as an airway conduit for tracheal intubation.

The i-gel (Intersurgical Ltd., Wokingham, England) is a cuffless, single-use supraglottic airway device designed to provide a more effective seal than the uLMA, thus eliminating problems 3-5 described above with the addition of a gastric drain. Made of a gel-like thermoplastic elastomer, the i-gel has an anatomically-designed mask that allows quick, easy insertion and can accurately position itself over the laryngeal framework to provide a reliable perilaryngeal seal without the need for an inflatable cuff. In a preliminary study, the peak airway pressures were found to be above 30 cm H2O with a sustained leak pressure of 24 cm H2O versus an average of 18-21 cm H2O seen with the cLMA. According to the 100 patient trial, the i-gel is easier to insert, it has better sealing properties and there is no cuffed inflates.

This clinical study has been designed to compare the i-gel and the uLMA, as to ease of placement, ventilation during mechanical ventilation, proper positioning, seal pressures, the patency of the drain tube, and finally, any complications with their use. Fiberoptic observations through each device will provide information in relation to the epiglottis and the distal opening of the device.

Enrollment

50 patients

Sex

All

Ages

18 to 80 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  1. The subjects will be adult surgical candidates aged 18-80, ASA I-II, Mallampati I or II, presenting for elective surgery who require general anesthesia in whom tracheal intubation is not necessary.
  2. Both male and female patients will be included.

Exclusion criteria

Patients will be excluded from the study if they present as Mallampati III or IV, ASA III-V or emergency status. Additionally, they will be excluded if they meet one of the contraindication criteria of the LMA including:

  1. obesity, (BMI > 35 kg/m2)
  2. pregnancy
  3. history of gastric regurgitation, heart burn, ileus or "full stomach"
  4. history of low pulmonary compliance or high pulmonary resistance
  5. known history of difficult endotracheal intubation or signs suggesting the possibility of difficult intubation
  6. pharyngeal pathology
  7. upper airway obstruction due to laryngeal pathology

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

50 participants in 2 patient groups

i-gel-SGA
Experimental group
Description:
Patients who received i-gel supraglottic device (i-gel airway) for intubation
Treatment:
Device: i-gel airway (Intersurgical Ltd., Wokingham, England)
LMA-Unique
Active Comparator group
Description:
Patients who received the Laryngeal Mask Airway-Unique (uLMA) for intubation
Treatment:
Device: Laryngeal Mask Airway-Unique

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems