Status
Conditions
Treatments
About
The purpose of this study is to evaluate a new disposable supra-glottic airway device, the i-gel airway (Intersurgical Ltd., Wokingham, England). We propose to test its ease of insertion, position within the airway, drain tube patency and anatomic sealing properties during mechanical ventilation in non-obese anesthetized patients undergoing elective general surgery. The study device will be compared to the current standard in the industry, the LMA Unique.
Full description
During the past decade, several pharyngeal airways have been introduced for airway management, such as the Laryngeal Mask Airway (LMA), the Cobra perilaryngeal airway, the Esophageal Tracheal Combitube (ETC), the EasyTube, the Laryngeal Tube6, and the Streamlined Liner of the Pharyngeal Airway (SLIPA). These airway devices have become very popular because of their ability to maintain an airway without perturbing the trachea and can be used in patients without muscle relaxation who are only lightly anesthetized.
The LMA Classic (cLMA) generally provides an adequate airway, but certain problems remain:
The LMA Unique (uLMA) is a disposable, inflatable supraglottic airway device that is based on the LMA Classic design which has been used as the "model" in the industry. It has been listed as a commonly accepted device for routine and rescue airway management and is now listed in the American Society of Anesthesiologists (ASA) Difficult Airway Management Algorithm as an airway conduit for tracheal intubation.
The i-gel (Intersurgical Ltd., Wokingham, England) is a cuffless, single-use supraglottic airway device designed to provide a more effective seal than the uLMA, thus eliminating problems 3-5 described above with the addition of a gastric drain. Made of a gel-like thermoplastic elastomer, the i-gel has an anatomically-designed mask that allows quick, easy insertion and can accurately position itself over the laryngeal framework to provide a reliable perilaryngeal seal without the need for an inflatable cuff. In a preliminary study, the peak airway pressures were found to be above 30 cm H2O with a sustained leak pressure of 24 cm H2O versus an average of 18-21 cm H2O seen with the cLMA. According to the 100 patient trial, the i-gel is easier to insert, it has better sealing properties and there is no cuffed inflates.
This clinical study has been designed to compare the i-gel and the uLMA, as to ease of placement, ventilation during mechanical ventilation, proper positioning, seal pressures, the patency of the drain tube, and finally, any complications with their use. Fiberoptic observations through each device will provide information in relation to the epiglottis and the distal opening of the device.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Patients will be excluded from the study if they present as Mallampati III or IV, ASA III-V or emergency status. Additionally, they will be excluded if they meet one of the contraindication criteria of the LMA including:
Primary purpose
Allocation
Interventional model
Masking
50 participants in 2 patient groups