Comparison of Nasal and Forehead Oximetry in Critically Ill Patients at Risk for Decreased Peripheral Perfusion

The Washington University logo

The Washington University

Status

Completed

Conditions

Hypotension
Pressure Ulcer

Treatments

Device: Nasal alar oxygen sensor

Study type

Interventional

Funder types

Other

Identifiers

NCT02382133
201408123

Details and patient eligibility

About

Continuous pulse oximetry monitoring is the standard of care in critically ill patients in emergency departments, operating rooms and intensive care units. In patients with poor peripheral perfusion (low blood flow) due to peripheral vascular disease, low body temperature, or shock and the use of medications to raise the blood pressure, clinicians have difficulty obtaining an accurate measurement. This study compares the accuracy of forehead oximetry sensors to nasal alar sensors to lab oximetry measures and on the rate of device related pressure ulcers with both.

Full description

Continuous pulse oximetry monitoring is the standard of care in critically ill patients in emergency departments, operating rooms and intensive care units. In patients with poor peripheral perfusion (low blood flow) due to peripheral vascular disease, low body temperature, or shock and the use of medications to raise the blood pressure, clinicians have difficulty obtaining an accurate measurement. Several studies have demonstrated the utility of forehead sensor measurements under these clinical conditions. Forehead sensor measurement is considered to be a more central measurement than with digit or ear sensors. However the sensor requires a head band for accurate measurement. On a regular basis, the forehead sensor has led to pressure ulcer development at Barnes-Jewish Hospital despite following vendor recommendations for alternating placement every 8 hours from one side of the forehead to the other. An alternate sensor placed on the nose has recently demonstrated rapid detection of induced drops in oxygen saturation. It has also demonstrated correlation with arterial oxygen saturation measured in a clinical laboratory. The oxygen saturation measurement from the nose is also considered a central measurement. However, studies of the nose sensor were conducted in healthy subjects or during anesthesia care over several hours. Therefore, research is needed to examine the accuracy of the nose sensor in the ICU patient population. In addition, due to concerns for sensor related pressure ulcers in patients with decreased perfusion, the sensor needs to be evaluated for extended periods of time.

Enrollment

43 patients

Sex

All

Ages

18 to 90 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Presence of an existing arterial catheter for blood sampling and one of the following:

  2. Difficulty obtaining a consistent signal from a digit or ear sensor or

  3. On pressors of at least 0 .10 mcg/kg/min of norepinephrine or

  4. Core temperature < or equal to 35 degrees C

Exclusion criteria

  1. Anatomic impediments (burns, wounds, dressings, etc.) to placement of the sensor on the forehead or nasal alar
  2. History of known dyshemoglobinemias evidenced by carboxyhemoglobin levels > 10% or methemoglobin level > 2%
  3. Severe anemia with hemoglobin < 5 g/dL
  4. Pregnant women

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

43 participants in 1 patient group

Nasal alar oxygen sensor
Other group
Description:
Application of a nasal alar oxygen sensor
Treatment:
Device: Nasal alar oxygen sensor