About

Catheter ablation in the treatment of atrial fibrillation (i.e. pulmonary vein isolation) is now the most effective method of prevention of arrhythmia recurrence. Use of 3D electroanatomical system is now a golden standard.

Background hypothesis is that automatic algorithm collecting ablation points during pulmonary vein isolation (with certain catheter stability time, range of motion, and catheter-tissue contact force) prevents forming the gaps in the ablation line, thus preventing pulmonary vein reconnection and AF recurrence. The aim of the trial will be 1:1 comparison of the two methods of pulmonary vein isolation: with manual vs. automatic collection of ablation points using CARTO system and contact force catheter.

Full description

Atrial fibrillation (AF) is the most common sustained supraventricular arrhythmia. It increases the risk of hospitalization and all-cause mortality. AF causes about 5-fold increase in the risk of stroke and 3-fold increase in the risk of heart failure.

Catheter ablation in the treatment of AF (i.e. pulmonary vein isolation) is now the most effective method of prevention of arrhythmia recurrence, especially in paroxysmal AF. Still, efficacy of one procedure in a 1-year follow-up is between 20 and 80%, depending on demographic and clinical factors (concomitant diseases), and on the form of the arrhythmia (paroxysmal-persistent), it also depends on the method of ablation used and the experience of the centre. In a big European registry including over 1,300 patients antiarrhythmic drugs-free efficacy of catheter ablation in AF in 1-year follow-up was about 40%. Major finding in patients with AF recurrence after catheter ablation is pulmonary vein reconnection, so decreasing the risk of pulmonary vein reconnections seems crucial to diminish the risk of AF recurrence. Several novel technologies have been proposed lately to improve efficacy of AF ablation, their real importance needs validation in a clinical trial.

Current standard is radiofrequency (RF) ablation with manual collection of ablation points (by operator or assistant). Automatic algorithm collect ablation points with additional criteria: catheter stability time, range of motion, and catheter-tissue contact force. The operator can see more precisely where the RF current has been applied and where are the gaps in the line.

Background hypothesis is that automatic algorithm collecting ablation points (with certain catheter stability time, range of motion, and catheter-tissue contact force) prevents forming the gaps in the ablation line, thus preventing pulmonary vein reconnection and AF recurrence. The aim of the trial will be 1:1 comparison of the two methods of pulmonary vein isolation: with manual vs. automatic collection of ablation points using CARTO system and contact force catheter.

Enrollment

90 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • patients with symptomatic atrial fibrillation qualified to catheter ablation according to current standards

Exclusion criteria

  • lack of informed consent
  • two previous pulmonary vein isolations

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

90 participants in 2 patient groups

Visitag group
Experimental group
Description:
Ablation using CARTO system. Visitag module: automated algorithm to collect RF ablation points using Visitag module. Criteria of ablation point: catheter stability range of motion ≤2.5mm, catheter stability time \>15sec, contact force \>5g over \>50% of time. Optimal contact force suggested: 10-40g.
Treatment:
Procedure: Ablation using CARTO system
Control group
Active Comparator group
Description:
Ablation using CARTO system. Manual collection of RF ablation points by operator or by assistant. Optimal contact force suggested: 10-40g.