Status
Conditions
Treatments
About
Phototherapy has served as a primary treatment for hyperbilirubinemia in newborn populations. The light emitted through phototherapy interacts with bilirubin at the skin level to transform it into water-soluble products eliminated in urine and stool. Efficacy of phototherapy relies on the irradiance dispensed at the skin level by the treatment and on the surface area of skin exposed. The purpose of this Investigator-initiated, prospective, two-arm, randomized control investigation is to compare the effect of a novel, newly available, FDA cleared, phototherapy device (Neolight Skylife) with the standard phototherapy treatments used in HonorHealth newborn nurseries (Natus-Neo Blue Blanket and GE Bili Soft Blanket) on healthy, newborns ≥ 35 weeks + 0 days Gestational Age (GA) at the time of birth in the treatment of hyperbilirubinemia. We hypothesize that the unconjugated bilirubin level will be comparably reduced across each treatment arm from baseline to 12 and 24 hour intervals.
Full description
This is an investigator-initiated, prospective, two-arm randomized control investigation to examine the mean values in patients' unconjugated bilirubin level for a new, FDA cleared device (Neolight Skylife) with the standard phototherapy treatment. Patient data on unconjugated bilirubin level, pressure ulcer and body temperature will be evaluated at baseline, 12-hours post-intervention, 24 hours post-intervention and at discharge.
Neolight Skylife is a compact device that offers phototherapy to infants across all neonatal beds, supplanting multiple, enclosure specific phototherapy devices. Neolight Skylife weighs less than 10 lbs. and is ergonomically designed for portability that allows for easy carrying of the device between beds. Neolight Skylife offers the choice between treatment intensity levels. Neolight Skylife utilizes blue Light-Emitting Diodes (LEDs) to achieve low irradiance of 30 plus or minus 5 μw/cm²/nm, and high irradiance of 45 plus or minus 10, μw/cm²/nm. Neolight Skylife emits light in a narrow bandwidth between 430-475 nm. This light bandwidth corresponds to the spectral absorption of light by bilirubin, and is thus considered to be the most effective for treatment. Neolight Skylife eliminates the risk of UV exposure typically seen with phototherapy treatment through the use of blue LEDs, as this light source does not emit significant energy in the ultraviolet (UV) spectrum. However, as with all phototherapy treatment, protective eye coverings are used to protect the baby's eyes from excessive light exposure.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Provision of at least one parent/legal guardian's signed and dated informed consent form
Stated willingness to comply with all study procedures and availability for the duration of the study
Infants born after 35 weeks and 0 days of gestation
Infants who developed significant hyperbilirubinemia Infants who developed significant hyperbilirubinemia per BiliToolTM plot requiring phototherapy as determined by the attending neonatologist utilizing the American Academy of Pediatrics'
Exclusion criteria
Participants will be screened on the following exclusion criteria at the time of enrollment:
As identified throughout the course of the investigation, additional exclusion criteria include:
Primary purpose
Allocation
Interventional model
Masking
72 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov