The overarching aim of this proposal is to examine the feasibility of the Q-NRG+ indirect calorimetry device and its agreement with (Vmax) Encore indirect calorimetry device in mechanically ventilated children. The overall hypothesis of this study is that the Q-NRG+ will provide minute-to-minute oxygen consumption (VO2) and carbon dioxide production (CO2) measurements that are in agreement with those obtained by the standard indirect calorimetry device currently used at our institution (Vmax Encore).
Full description
Indirect calorimetry allows accurate measurement of energy expenditure in this population but current technology is cumbersome and time-consuming, and has many limitations that exclude a majority of criticaly ill children. A new device was recently developed to address some of the limitations of IC devices and is widely endorsed for IC measurements in critically ill adults. The Q-NRG+ IC device incorporates an easier gas calibration technique to facilitate faster start up, and a micro-mixing chamber (2ml) allows rapid achievement of steady state gas exchange measurement. The device may address some of the current barriers for the use of indirect calorimetry in critically ill children. A device with short calibration time and reliable measurements could enhance the ability of clinicians to deliver individualized energy prescriptions for patients.
Description of Study Treatments
Following informed consent, the following steps will be followed for the study procedure:
Definitions of Outcomes/Endpoints The primary variables to be collected are steady state measurements of VO2 and VCO2 from both indirect calorimetry devices. Steady state will be defined as a period of greater than five minutes with coefficient of variation of the VO2 and VCO2 measurements of less than 10%. If steady state is not achieved, energy calculations will not be included in data analysis. Secondary variables to be collected include total time to obtain indirect calorimetry measurement, from arrival at the bedside to completion of the study. Steady state conditions will be defined using existing institutional practice.
Data Collection Methods and Assessments Descriptive characteristics will also be collected for each patient including age, weight, height, diagnosis, severity of illness, length of ICU stay, vital signs, and ventilator settings. We will also collect endotracheal tube size, presence of cuff, leak percentage. We will also collect information about medications, including inotropes and vasopressors, sedation medications (as well as SBS score) and nutrition parameters. Markers of inflammation, WBC and CRP will be collected from the patient chart.
Statistical Analysis Descriptive statistics will be computed for measured REE, VO2 and VCO2 and Bland-Altman analysis will be utilized to quantify the mean bias and limits of agreement between devices. Acceptable limits of agreement between the devices will be +/- 20%. VO2, CO2 will be reported as means (SD). The time to steady state and total time of IC measurement will be compared using a T-test (if normally distributed) or Mann-Whitney U-test (if not normally distributed).
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
40 participants in 2 patient groups
Loading...
Central trial contact
Nilesh M Mehta, MD; Ben D Albert, MD
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal