Comparison of Two Different Types of Mechanical Ventilation Weaning in Patients in the ICU

H

Hospital Israelita Albert Einstein

Status and phase

Completed
Phase 4

Conditions

Weaning Failure

Treatments

Other: Conventional weaning protocol
Device: SmartCare

Study type

Interventional

Funder types

Other

Identifiers

NCT02122016
SmartCare\HIAE11

Details and patient eligibility

About

Mechanical ventilation is widely used for ICU patients as a lifesaving procedure. However, it is associated with several complications, such as ventilator-associated pneumonia and the increase of hospital morbidity and mortality. To avoid such complications, we need to wean these patients off the ventilator as soon as possible. This must however be done at the right time to avoid other complications, such as the need for re-intubation. For this reason, it is important to have a specific weaning protocol, which will reduce the time on mechanical ventilation, and avoiding the need for re-intubation and other complications. Recently, an argument has developed as to which weaning protocol would be more appropriated, and whether a computer driven weaning protocol could have better results than the conventional weaning protocols focusing on daily screening and daily interruption of sedation followed by a spontaneous breathing test. Our objective is to compare mechanical ventilation times, weaning success up to 48 hours after extubation, re-intubation rates between a group with computer driven weaning protocol (SmartCare) versus a weaning protocol with daily weaning screens and spontaneous breathing trials in ICU patients ventilated for more than 24 hours.

Full description

Background: Mechanical ventilation (MV) weaning is commonly performed using Spontaneous Breathing Trials (SBT) with pressure support ventilation after a daily weaning screen [1]. Recently there has been an increased interest in automatic weaning trials, which consists of closed-loop ventilation, using ETCO2 monitoring during SBT [1, 2]. So far, there has been no clinical evidence to compare automatic weaning trials with those of SBT.

Objective: To compare MV weaning times between an Automatic Weaning Ventilation System (SmartCare/PS) and SBT groups.

Methods: A randomized, controlled study performed at a general ICU. Adult patients were enrolled who were ventilated for more than 24 hours. Tracheostomies patients, those with neurological conditions, and a Glasgow coma scales lower than 10 were excluded. Patients were randomized to either the control or Smart Care group. All patients were ventilated with a Drager Evita XL (Drager Medical, Lubeck, Germany) ventilator with SmartCare/PS software version 1.1 available for use immediately prior to randomization. The Control group consisted of a daily weaning screen and SBT with pressure support ventilation. If patients tolerated SBT, they were extubated. Smart Care group patients were also submitted to a daily weaning screen, after which they were ventilated with the SmartCare/PS mode. MV and weaning time, maximum inspiratory pressure (MIP), maximum expiratory pressure (MEP), vital capacity (VC), respiratory frequency to tidal volume ration (f/Vt), use of non-invasive ventilation (NIV) post extubation, and re-intubation rate we evaluated.

Enrollment

70 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Recovery from the causes that had led to mechanical ventilation
  • Capacity to initiate a spontaneous breathing effort
  • Spontaneous eye opening and responsiveness even with low doses of sedation
  • Oxygen inspired fraction lower than 50% with oxygen pulse oximeter higher than 95%
  • Positive end-expiratory pressure under 10 cmH2O
  • Hemodynamic stability
  • Vasopressor drugs lower than 0.05mcg/ml/kg

Exclusion criteria

  • Tracheotomized patients
  • Neurological sequels with a poor prognostic (post cardiorespiratory arrest or central neurological injury)
  • Glasgow scale lower than 10

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

70 participants in 2 patient groups

SmartCare
Experimental group
Description:
A computer driven weaning ventilator, using closed-loop ventilation, taking into account patients lung mechanics and exhaled CO2.
Treatment:
Device: SmartCare
Conventional weaning protocol
Active Comparator group
Description:
A conventional weaning protocol consisting of a daily weaning screen, which is performed by physiotherapist. All patients who are mechanically ventilated for more than 24 hours are given a spontaneous breathing trial.
Treatment:
Other: Conventional weaning protocol