ClinicalTrials.Veeva

Menu

Continuous Glucose Monitoring Devices in Hospitalized Veterans With Diabetes

VA Office of Research and Development logo

VA Office of Research and Development

Status

Enrolling

Conditions

Hypoglycemia
Diabetes Mellitus, Type 2

Treatments

Other: POC (Point of Care)
Device: GTS (Continuous Glucose Monitoring)

Study type

Interventional

Funder types

Other U.S. Federal agency

Identifiers

NCT03508934
CX001825-01 (Other Grant/Funding Number)
ENDA-022-17F

Details and patient eligibility

About

More than 25% of the patients admitted in the general wards have a history of Diabetes Mellitus (DM). Up to 30% of the hospitalized diabetics develop hypoglycemia (low glucose values); a condition that is associated with seizures, cardiac arrhythmias, and even death. In Veterans, the prevalence is disproportionally higher. It is estimated that 40-50% of hospitalized Veterans are diabetics. In this clinical trial the investigators describe the development of a novel system, the Glucose Telemetry System (GTS), with which glucose values can be wirelessly transmitted from the patient's bedside to a monitor device at the nursing station. The goal of this work is to develop a more effective glucose surveillance system at the general wards, which can decrease hypoglycemia in the hospital and improve clinical outcomes.

Full description

More than 25% of patients admitted to general wards/non Intensive Care Unit (non-ICU) setting have a history of Diabetes Mellitus (DM); and as for 2012, $125 billion dollars were costs associated with hospitalization of diabetics in the United States (US). Up to 30% of the hospitalized diabetics develop hypoglycemia, a condition that is associated with higher hospital charges, prolonged length of stay, and increased morbidity and mortality.

Reducing hypoglycemic events in the inpatient setting has led hospitals to develop hypoglycemia prevention policies; policies which are however limited by the infrequent Point of Care (POC) capillary blood glucose testing in the general wards. Continuous Glucose Monitoring (CGM) devices represent additional ways to monitor blood glucose levels. Only a limited number of studies have examined the use of CGM devices in the non-ICU setting. In all these studies, CGM use was found to be superior compared to POC in hypoglycemia detection. However, as the results of CGM were blinded (alarms were turned off) for both the investigators and the participants, interventions to prevent hypoglycemia were not performed. Additionally, one major limitation of CGM technology is that CGM receiver/monitor needs to be located in the patient's room, due to Bluetooth Technology signal-strength restrictions, necessitating nurses to enter frequently the patient's room in order to check CGM glucose values. In the current application, the investigators are going to evaluate whether an innovative system that the investigators call "Glucose Telemetry System" (GTS) can decrease hypoglycemia and improve clinical outcomes in hospitalized Veterans with DM2.

Discovering novel ways to monitor glucose values in the hospital setting could have a significant impact in preventing hypoglycemia in the inpatient setting- a condition that is associated with adverse clinical outcomes. The investigators believe that this proposal is highly innovative. The trial may lead to future wider use of CGM in hospitalized patients with DM who are at a higher risk for hypoglycemia, similar to the way that the investigators use cardiac telemetry for patients who are at an increased risk for developing arrhythmias.

Enrollment

244 estimated patients

Sex

All

Ages

21+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Veterans with history of DM2 managed with insulin (either basal bolus, basal only or basal with per os DM medications), admitted to the Baltimore VA Medical Center, who have at

    • least 1 risk factor of hypoglycemia

Exclusion criteria

  • Veterans with history of type 1 DM.
  • Veterans with history of DM2 managed with diet or any combination of oral antidiabetic drugs only.
  • Veterans hospitalized with significant hyperglycemia or diabetic ketoacidosis
  • Pregnant Veterans
  • Veterans receiving glucocorticosteroids in doses (equivalent) to 20 mg of hydrocortisone/day
  • Veterans that are expected to require a hospital stay <3 days will also be excluded

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

244 participants in 2 patient groups, including a placebo group

Intervention group (Continuous Glucose Monitroring and POC)
Active Comparator group
Description:
Hospitalized patients with DM2 will be monitored with Glucose Telemetry System (GTS) and Point of Care (POC) finger-stick blood glucose levels with application of hypoglycemia prevention protocol (activated based the GTS lower glucose alarms)
Treatment:
Device: GTS (Continuous Glucose Monitoring)
Other: POC (Point of Care)
Control group (Point of Care-POC)
Placebo Comparator group
Description:
Hospitalized patients with DM2 will be monitored with POC blood glucose levels and application of hypoglycemia prevention protocol (activated based the POC values)
Treatment:
Other: POC (Point of Care)

Trial contacts and locations

1

Loading...

Central trial contact

Ilias Spanakis, MD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems