Correlation Between Computer Tomography Angiography and D-Dimer Level for the Diagnosis of Pulmonary Embolism

Z

Zulekha Hospitals

Status

Completed

Conditions

D-Dimer as an Early Detector of Pulmonary Embolism

Treatments

Diagnostic Test: D-Dimer vs CTPA

Study type

Observational

Funder types

Other

Identifiers

NCT05862220
ZH-12-2022-01

Details and patient eligibility

About

A blood sample was taken before starting the patients on any thrombolytic treatment. The positivity threshold for D-Dimer was above 250 ng/ml. CTPA was performed after performing blood sampling. Patients with confirmed pulmonary embolisms were admitted to ICU for continued monitoring of vitals, consciousness level, and signs of tissue perfusion. Signs of shock or hemodynamic instability should be observed regularly. Patients were managed in the ICU with anticoagulants by parenteral use. The most commonly used items were Heparin, either Unfractionated (UFH) or low-molecular-weight heparin (LMWH).D-dimer levels can leverage to detect PE. D-dimer levels can help in guiding the option of CTPA and the initiation of treatment for patients with suspected PE.

Full description

A blood sample was taken before starting the patients on any thrombolytic treatment. The positivity threshold for D-Dimer was above 250 ng/ml. CTPA was performed after performing blood sampling. Patients with confirmed pulmonary embolisms were admitted to ICU for continued monitoring of vitals, consciousness level, and signs of tissue perfusion. Signs of shock or hemodynamic instability should be observed regularly. Patients were managed in the ICU with anticoagulants by parenteral use. The most commonly used items were Heparin, either Unfractionated (UFH) or low-molecular-weight heparin (LMWH).Presenting symptoms were mainly dyspnea, chest pain or discomfort, cough, and shortness of breath. Twenty-four patients of the total number of cases were positive for CTPA while four patients were negative for PE by CTPA. embolism was detected in the anterior, posterior, medial, and lateral basal segmental branches of the right lung, the lateral, posterior, and anterior basal segmental branches of the left lung, and the posterior segmental branch of the left lung. The D-dimer test and CTPA both provided similarly accurate PE diagnoses with no significant differences between them. There were 28 patients total, 3 of those patients had D-dimer levels below the cut-off value of 250 ng/ml, whereas the remaining 25 had D-dimer levels over the diagnostic threshold. Those with a positive CTPA diagnosis of PE had greater levels of D dimers than those with a negative CTPA diagnosis of PE. plasma D-dimer concentration did not correlate with the cross-sectional diameter of the blocked pulmonary vessel.D-dimer levels can leverage to detect PE. D-dimer levels can help in guiding the option of CTPA and the initiation of treatment for patients with suspected PE.

Enrollment

28 patients

Sex

All

Ages

22 to 74 years old

Volunteers

Accepts Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria: Acute chest pain, dyspnea, tachypnea, and suspicion of PE -

Exclusion Criteria:the history of PE, the administration of anticoagulant medication before blood sampling, an allergic response to the CTPA contrast agent, impaired hepatic function or renal function, inability to cooperate during examinations, and an absence of relevant medical records for analyses

Trial design

28 participants in 2 patient groups

D-Dimer group
Description:
A blood sample was taken before starting the patients on any thrombolytic treatment. The latex agglutination test was used to measure plasma D-dimer level; this was done using a Sysmex CA-7000 automatic coagulation unit. The positivity threshold was above 250 ng/ml.
Treatment:
Diagnostic Test: D-Dimer vs CTPA
CTPA group
Description:
CTPA was performed after performing blood sampling using Siemens Somatom definition AS 24 slice scanners. Non-ionic water-soluble contrast Omnipaque 350 mg I/mg or Visipaque 320 mg I/mg was injected at 4 mm/s maximum dose 100 ml using a Medtron pressure injector.
Treatment:
Diagnostic Test: D-Dimer vs CTPA