ClinicalTrials.Veeva

Menu

Correlation Between Corneal Topographic Patterns and Refractive Status Of The Eye in Sohag City,Egypt

S

Sohag University

Status

Enrolling

Conditions

Eye Change

Treatments

Diagnostic Test: Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.

Study type

Interventional

Funder types

Other

Identifiers

NCT05626075
Soh-Med-22-07-2014

Details and patient eligibility

About

To evaluate corneal topographic pattern & its correlation with refractive status of the eye .

Full description

This study will be established in The Future Center for refractive surgery, Sohag, Egypt.

This study will include 100 eyes of patients aged over 15 years. All patients were subjected to topography imaging.

Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.

The scheimpflug principle describes the optical imaging condition when the plane of an object is not parallel to the film of the camera and has to cut each other in one line or one point of intersection with the advantage to achieve wide depth of focus.

Scheimpflug imaging attains a wide and high depth-of-focus , providing sharp images that include information from an anterior corneal surface through to the posterior crystalline capsule; this depends mainly on media transparency and pupil size .

Enrollment

100 estimated patients

Sex

All

Ages

15+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Patients aging more than 15 years old
  • All patients are with visual acuity (uncorrected, with habitual correction, and best spectacle correction).
  • There is no restrictions on the range and regularity of keratometry.

Exclusion criteria

  • Patients with a history of any trauma to the eye.

  • Patients with recent contact lens wear.

  • history of ocular surgery .

  • Patients with distance corrected visual acuity or abnormal retinoscopy examination (e.g., scissoring reflex).

    1. If there was any error in reading the topographic map. 6. Patients with anemotropic refraction.

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

100 participants in 4 patient groups

group Low Myopia
Experimental group
Description:
1. Patients with low myopia aging more than 15 years old 2. All patients are with visual acuity (uncorrected, with habitual correction, and best spectacle correction). 3. There is no restrictions on the range and regularity of keratometry
Treatment:
Diagnostic Test: Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.
group high myopia
Experimental group
Description:
1. Patients with high myopia aging more than 15 years old 2. All patients are with visual acuity (uncorrected, with habitual correction, and best spectacle correction). 3. There is no restrictions on the range and regularity of keratometry
Treatment:
Diagnostic Test: Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.
group Hypermetropia
Experimental group
Description:
1. Patients with hypermetropia aging more than 15 years old 2. All patients are with visual acuity (uncorrected, with habitual correction, and best spectacle correction). 3. There is no restrictions on the range and regularity of keratometry
Treatment:
Diagnostic Test: Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.
group mixed astigmatism
Experimental group
Description:
1. Patients with mixed astigmatism aging more than 15 years old 2. All patients are with visual acuity (uncorrected, with habitual correction, and best spectacle correction). 3. There is no restrictions on the range and regularity of keratometry
Treatment:
Diagnostic Test: Using Oculus Pentacam® which is s a rotating Scheimpflug camera. The rotational measuring procedure generates Scheimpflug images in three dimensions.

Trial documents
1

Trial contacts and locations

1

Loading...

Central trial contact

Mohamed Iqbal, MD.PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems