Cough Assist Device in Mechanically Ventilated Patients

A

Assiut University

Status

Not yet enrolling

Conditions

Mechanically Ventilated Patients

Treatments

Device: Mechanical insufflation/exsufflation
Device: Conventional tracheal suctioning

Study type

Interventional

Funder types

Other

Identifiers

NCT05480371
cough assist device

Details and patient eligibility

About

Aspiration of respiratory secretions is a frequently needed procedure in intubated patients .

Cough is an important defence mechanism to clear mucus from the upper and lower airways . The presence of an endotracheal tube impairs the ability to cough.There are a number of techniques to mobilise sputum and optimise airway clearance for invasively ventilated patients. Endotracheal suctioning is the most common intervention used to remove retained airway secretions from within the endotracheal tube, trachea and upper airways .Mechanical insufflation-exsufflation (MI-E) aids sputum clearance from upper and lower airways. This technique augments inspiratory and expiratory flows to improve sputum mobilisation, through the application of rapidly alternating positive and negative pressure, which approximates a normal cough

Full description

Critically ill patients under invasive ventilation are at risk for sputum retention . Aspiration of respiratory secretions is a frequently needed procedure in intubated patients .

Cough is an important defence mechanism to clear mucus from the upper and lower airways . The presence of an endotracheal tube impairs the ability to cough. This prevents the enhancement of cough velocity . Furthermore, critically ill patients frequently have an impaired or no cough reflex due to depressed levels of consciousness, sedation, muscle weakness or muscle paralysis. Sputum retention, resulting from an inability to cough effectively, is one cause of extubation failure which in turn is associated with increased mortality.

There are a number of techniques to mobilise sputum and optimise airway clearance for invasively ventilated patients. Endotracheal suctioning is the most common intervention used to remove retained airway secretions from within the endotracheal tube, trachea and upper airways . Endotracheal suctioning though is not effective for clearing secretions from the lower airways .

New technologies and advanced methods have been developed to increase the effectiveness of mucus clearance in patients with acute respiratory failure, including mechanical insufflation-exsufflation devices. This technique has been described as an effective aid for mucus clearance in patients with chronic muscle weakness or neuromuscular disease.

Mechanical insufflation-exsufflation (MI-E) aids sputum clearance from upper and lower airways. This technique augments inspiratory and expiratory flows to improve sputum mobilisation, through the application of rapidly alternating positive and negative pressure, which approximates a normal cough .

Enrollment

200 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Adult patients of both sexes on mechanical ventilation in RICU with any respiratory disease

Mechanically ventilated Patients without facial trauma

Mechanically ventilated Patients hemodynamically stable

Exclusion criteria

Patients diagnosed with barotrauma

Patients diagnosed with pneumothorax

History of bullous emphysema Known susceptibility to pneumothorax or pneumo-mediastinum

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

200 participants in 2 patient groups

Conventional endotracheal suctioning
Active Comparator group
Description:
Tracheal suctioning will be performed following the American Association for Respiratory Care recommendations: closed suction system, suction catheter with maximal internal-to-external diameter ratio of 0.5, delivery of 100% oxygen 30 s immediately before and 1 min after the procedure, duration of 15 s, and vacuum pressure of ±150 mmHg
Treatment:
Device: Conventional tracheal suctioning
mechanical insufflation exsufflation
Experimental group
Description:
The mechanical insufflation-exsufflation will be performed with the which will be applied 5 times in 5cough cycles in automatic mode, with insufflation and exsufflation pressures of + 40/-40 cmH2O, respectively. The duration of each phase was 3 s, without pause, and tracheal suctioning will be performed at the end of the procedure. Hyperoxygenation (100% O2) will be performed for 1 min before applying each technique and a 20 s interval will be allowed between repetitions. The secretion collected after each procedure will be stored in a disposable bronchial secretion collector for later weighing
Treatment:
Device: Mechanical insufflation/exsufflation