ClinicalTrials.Veeva

Menu

CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times

P

Parc de Salut Mar

Status

Enrolling

Conditions

Flutter

Treatments

Procedure: Confluent areas
Procedure: Wave Speed
Procedure: CTI line
Procedure: Voltage

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT05709795
OMNIFLUTTER

Details and patient eligibility

About

Prospective randomized study involving patients with typical flutter (TF) undergoing cavo-tricuspid isthmus (CTI) radiofrequency ablation. The aim is to compare the results of 3 different new ablation strategies using Omnipolar technology to classic linear ablation.

The investigators´ aim is to compare the effectiveness, safety and procedure times of CTI ablation with 3 different strategies using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter to optimize radiofrequency (RF) and fluoroscopy times with classical linear ablation.

The number of patients needed to prove the investigators´ hypothesis is of at least 50 per group (total of 200 prospective patients

Full description

Background Ablation procedures for CTI-dependent TF have classically been guided by fluoroscopy and intracavitary electrograms from diagnostic catheters placed in the right atrium (RA), the coronary sinus (CS) and the CTI (ablation catheter). Over the last few years, the use of navigators has increased considerably not only for complex procedures, but also for simple procedures, with the aim of reducing and even completely eliminating irradiation to both the patient and the operator (1). The investigators´ group is looking to characterize the high voltage and the low velocity regions in the CTI to minimize the procedure times. This has been addressed in a recent observational study with very good results.

Rationale There is increasing evidence of the benefits using 3D-systems not only to diminish fluoroscopy, but also to guide ablation targeting high voltage areas in the CTI (2-5). It is well known also the existence of low speed areas in the CTI, facilitating the presence of reentrant circuits (6,7). Currently, the investigators´ center performs all CTI ablation procedures using a 3D-navigator system, mostly with zero or minimal fluoroscopy. The investigators´ group has carried out a preliminary study with 13 patients to assess the effectiveness of CTI ablation with the use of the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter. In this observational study the investigators were able to characterize the high voltage and the low velocity regions in the CTI to minimize the RF lesions and procedure times. Acute bidirectional block was achieved in 100% of patients with an average fluoroscopy time of 1 ± 2 min (77% patients with zero fluoroscopy) and an average RF time of 5,7 ± 3,2 min (38% below 3 min). This results were significantly lower than results obtained with classical linear ablation: median fluoroscopy time 19.3 min, IQR 12.9 to 36.4 min, median fluoroscopy dose 3520.7 cGycm(2), IQR 1700.0 to 6709.0 cGycm(2).

From the investigators´ point of view this observational study, together with previous evidence justify a randomized study in order to confirm our hypothesis:

Hypothesis Omnipolar technology is able to guide the ablation procedure minimizing both the RF time and the fluoroscopy time (compared to linear ablation) by targeting only the critical regions on the CTI. Therefore Omnipolar technology will diminish RF time and fluoroscopy time/exposition compared to classical CTI ablation, and by means of this the investigators expect an inferior complications rate. Importantly acute success rate and 6 months follow-up recurrences rate will remain similar.

OBJECTIVES

  • Primary objectives: to optimize procedure times of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation.

    o Specific objectives: Fluoroscopy time, radiofrequency time, radiation dose, percentage of zero-fluoroscopy procedures, acute efficacy, complications rate.

  • Secondary objectives: to increase the effectiveness of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation.

    • Specific objectives: Recurrences rate at 6 months.

Enrollment

200 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients submitted to CTI ablation for TF
  • Age above 18 years

Exclusion criteria

• Life expectancy of <1 year

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

200 participants in 4 patient groups

Confluent areas
Experimental group
Description:
Ablation first of confluent areas of low wave speed and high voltage in the CTI
Treatment:
Procedure: Confluent areas
Wave Speed
Experimental group
Description:
Ablation first of areas of low wave speed in the CTI
Treatment:
Procedure: Wave Speed
Voltage
Active Comparator group
Description:
Ablation first of areas of high voltage in the CTI
Treatment:
Procedure: Voltage
CTI line
Active Comparator group
Description:
Direct CTI line performance (gold standard)
Treatment:
Procedure: CTI line

Trial contacts and locations

2

Loading...

Central trial contact

Ermengol Valles, PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems