ClinicalTrials.Veeva

Menu

Detecting Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring (CGM)

Stanford University logo

Stanford University

Status

Completed

Conditions

Neonatal Hypoglycemia

Treatments

Diagnostic Test: Standard of care glucose test

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Hypoglycemia is the most common metabolic problem faced after birth. The investigators will be studying the utility of using a continuous glucose monitoring(CGM) system to more closely monitor low blood sugars in newborns. The investigators will evaluate the number of hypoglycemic events detected using CGM and compare it to those detected using current standard of care screening methods.

Full description

A CGM will be subcutaneously inserted by trained staff on a healthy area of skin and will be calibrated according to the manufacturer's instructions. Blood glucose measurements will be taken using a blinded study glucometer to calibrate the device. Calibration by trained study staff will take place about every 12 hours. Sensor insertion sites will be monitored for infection throughout the course of the study by nursing and clinical staff or by trained study staff on an as needed basis. At the conclusion of the study, the CGM will be removed and assessed for signs of infection. Study duration will be up to 7 days while the patient is admitted to the hospital.

Participants will be randomized into 2 groups. The control group will have a blinded CGM in place for the duration of the study. The remote monitoring group will be blinded to clinical staff. This group will have a CGM connected to an iPod that sends continuous glucose data to the study phone and will be monitored 24/7 by study staff. If a blood sugar level of <46 mg/dl is detected, the infant will first be evaluated for positioning that could be causing a falsely low value. If the infant is re-positioned and CGM continues to show a blood sugar level of <46 mg/dl, study staff will prompt the nurse taking care of the patient to obtain a capillary glucose value to verify the low blood sugar and treat it as deemed appropriate by the clinical team.

The investigators will evaluate the number of hypoglycemic events that occur in the blinded CGM group versus the number that occur in the remote monitoring group to assess if the CGM is able to more sensitively detect low blood sugars in infants than current hospital standard of care measures.

Enrollment

21 patients

Sex

All

Ages

Under 7 days old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Infants who are at least 34 weeks gestation that are born to mothers with gestational or pre-gestational diabetes and are admitted to LPCH are eligible for the study.

Exclusion criteria

  • Infants <2,000 grams will be excluded from the study. Infants will also be excluded if they have an anomaly of the skin or subcutaneous tissue that would prevent proper adhesion, placement, and function of the sensor.

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

21 participants in 2 patient groups

Remote Monitoring CGM Group
Experimental group
Description:
Participants wear a CGM that is blinded at bedside (to participant and clinical staff) but remotely monitored by study staff. If a blood sugar less than 46 mg/dl occurs, the study staff receive a notification and ask the clinical staff to perform a confirmation standard of care glucose test.
Treatment:
Diagnostic Test: Standard of care glucose test
Blinded CGM Group
No Intervention group
Description:
Participants wear a blinded CGM during the study period. Values are blinded to study staff, participant, and clinical staff.

Trial documents
1

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems