Status
Conditions
Treatments
About
Purpose: The purpose of the study is to explore the efficacy of H1 deep TMS for the treatment of FMS.
Design: Prospective randomized sham controlled trial Study Population & sample size:forty (40) FMS subjects between 18-80 years of age.
No. of Centers: Four centers-
Name of device: The Brainsway Ltd. H1-Coil
Study Endpoints: Clinical outcome:
primary outcome Change in self-reported average pain intensity over the last 24 hours will be measured at the end point with the numerical scale (0 = no pain, 10 = maximal pain imaginable) of the VAS-FIQ.
secondary outcome
Change of sensory and affective pain dimensions will be measured at the end point using the McGill Pain Questionnaire.
Change of the impact of pain and FMS on quality of life, will be measured at the end point using the BPI items for pain interference.
change of sensitivity to painful stimuli will be evaluated by physical measurements:
Changes in cognitive functions in domains of attention, working memory, spatial memory, executive functions and social cognition will be measured at the beginning and end point of the study using the Penn Web-Based Computerized Neurocognitive Battery (WebCNP).
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
40 participants in 2 patient groups
Loading...
Central trial contact
Yuval Bloch, MD; Uri Nitzan, MD
Data sourced from clinicaltrials.gov