ClinicalTrials.Veeva

Menu

E-T Tube Cuff Pressure Change After Changing Position From Neutral to Hyperextension of Neck

K

Keimyung University

Status

Unknown

Conditions

Thyroidectomy

Treatments

Device: Mallinckrodt, COVIDIEN
Device: Endotracheal tube, Unomedica

Study type

Interventional

Funder types

Other

Identifiers

NCT02949856
2016-05-032-001

Details and patient eligibility

About

This study evaluates difference of the endotracheal tube cuff pressure between a tapered- versus a cylindrical- shaped cuff after changing from neutral to hyperextension of neck.

Fifty patients undergoing thyroidectomy are randomly allocated into two groups (tapered- and cylindrical-shaped cuff). Endotracheal tube cuff pressure is initially set at 20 cmH20 in the supine neutral position and is measured after the change to the neck extension.

Enrollment

50 estimated patients

Sex

All

Ages

18 to 70 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • American Society of Anesthesiologists physical classification 1-3, 18-70 year old, thyroidectomy

Exclusion criteria

  • difficult intubation, history of cervical disease, motion limitation of neck, morbid obesity

Trial design

Primary purpose

Prevention

Allocation

Randomized

Interventional model

Factorial Assignment

Masking

Single Blind

50 participants in 2 patient groups

Tapered
Experimental group
Description:
Mallinckrodt, COVIDIEN
Treatment:
Device: Mallinckrodt, COVIDIEN
Cylindrical
Active Comparator group
Description:
Endotracheal tube, Unomedical
Treatment:
Device: Endotracheal tube, Unomedica

Trial contacts and locations

0

Loading...

Central trial contact

Yong-Cheol Lee, MD, PhD

Data sourced from clinicaltrials.gov