ClinicalTrials.Veeva

Menu

ECG Belt to Assess Electrical Synchronization

P

Pugazhendhi Vijayaraman

Status

Completed

Conditions

Bradycardia
Heart Failure

Treatments

Device: ECG Belt

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT04583709
2020-0465

Details and patient eligibility

About

The objective of the study is to assess the utility of ECG Belt to understand the conduction and ECG characteristics of Left Bundle Branch Pacing (LBBAP) and His-Optimized Cardiac Resynchronization Therapy (HOT-CRT) and compare with preexisting data in traditional Cardiac Resynchronization Therapy (CRT) and Right Ventricular Pacing (RVP).

Full description

The objective of the study is to assess the utility of ECG Belt to understand the conduction and ECG characteristics of LBBP and HOT-CRT and compare with preexisting data in traditional CRT and RVP.

Specific Objective:

  • To demonstrate and establish electrical resynchronization using ECG Belt Research System in Left Bundle Branch Pacing (LBBP) and HOT-CRT.
  • To assess ECG Belt derived native conduction parameters and compare them to LBBP and HOT-CRT.
  • To compare with historic ECG belt parameters obtained for right ventricular pacing/ Biventricular pacing in prior studies.

The ECG Belt study is a prospective, single-center, investigational, pre-market research study. The study team will identify all patients who satisfy the inclusion and exclusion criteria. The study team will evaluate the ECG Belt Research System to assess the electrical characteristics of conduction system pacing in patients with preexisting LBBP or HOT-CRT.

Eligible patients would have successfully undergone LBBP using Medtronic 3830 lead. LBBP will be confirmed at implant using left bundle potentials recorded from the lead, ECG morphology during unipolar and bipolar pacing, peak LV activation time and lead depth in the LV septum by contrast at implant and 2D echo post-implant.

ECG belt would be used to record ECG during baseline rhythm, LBBP in unipolar and bipolar configurations and / or during HOT-CRT using His-Bundle Pacing (HBP) or LBBP. These ECG belt characteristics would then be compared with baseline and existing data on Right Ventricular RV pacing and traditional Biventricular pacing.

Enrollment

20 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Patients > 18 years of age

  2. Patient has a previously implanted LBBP lead for bradycardia indication or heart failure indication with one of the following at Geisinger within the last 5 years:

    • LBBP
    • LBBP+LV lead
    • HBP+LV
  3. Patient is willing to comply with all study procedures and be available for the duration of the study.

Exclusion criteria

  1. Inability to provide informed consent
  2. Pregnant
  3. Enrolled in a concurrent study that may confound the results of this study.

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 1 patient group

ECG Belt
Experimental group
Description:
ECG belt will be used to record ECG during baseline rhythm, LBBP in unipolar and bipolar configurations and / or during HOT-CRT using HBP or LBBP. These ECG belt characteristics would then be compared with baseline and existing data on RV pacing and traditional Biventricular pacing.
Treatment:
Device: ECG Belt

Trial documents
2

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems