Details and patient eligibility

About

Dental pulp tests are investigations that offer valuable diagnostic and treatment planning information to the dental clinician. EPT is a sensibility test that can be easily performed in clinical practice. Current study is to find the best conducting substance among readily available water-based gels and gel-based tooth pastes to evaluate the efficacy of electric pulp tester.

Full description

The study will be performed on dental students with written informed constant. The sample size of study is 100. There will two main groups of conductor materials used in the study: water-based gels (fluoride gel, electrode gel and chlorohexidine gluconate) and gel-based toothpastes (Colgate and Dentonic Ultrawhitening gel). All groups will be randomly applied to the same patient at a single visit. Two measurements will be recorded for each material and the average value of the two measurements will used. Then, the measurements will record, and a comparison will be made between different conductors.

Enrollment

100 estimated patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Healthy fully erupted teeth maxillary central incisors.
  • Study subjects above 18 years.
  • No systemic diseases and pregnancy

Exclusion criteria

  • Carious, decayed and periodontally affected teeth.
  • Taking anti-inflammatory drugs from last 2 weeks.
  • Taking cortisone for the last 6 month

Trial design

100 participants in 5 patient groups

Group 1: Fluoride gel
Description:
The fluoride gel used as conductive media for electric pulp tester in this group
Group 2:Electrode gel
Description:
In Group 2 electrode gel applied as conductive media for electric pulp test.
Group 3: chlorohexidine gluconate gel
Description:
chlorohexidine gluconate gel used as conductive media for electric pulp tester in group 3.
Group 4:Colgate gel toothpaste
Description:
Colgate gel toothpaste gel used as conductive media for electric pulp tester in group 4.
Group 5:Dentonic Ultrawhitening gel
Description:
Dentonic Ultrawhitening gel used as a conductive media in Group 5.