Effect of Different Fixed Lingual Retainers on Tooth Stability

M

Mustafa Kemal University

Status

Withdrawn

Conditions

Effect of Lingual Retainers on Tooth Stability

Treatments

Other: measuring tooth stability after orthodontic treatment using a Periotest® device.

Study type

Observational

Funder types

Other

Identifiers

NCT06284499
26308819120

Details and patient eligibility

About

Objective: The aim of this study was to compare the effect of different fixed lingual retainers (LRs) on tooth stability after orthodontic treatment using a Periotest® device.

Materials and methods: A total of 82 patients (43 females and 39 males; mean age = 18.61 ± 3.71 years) with no missing teeth in the lower inter-canine region were treated with fixed orthodontic mechanics. At the completion of the orthodontic treatment, each patient was fitted with either Ortho FlexTech (Reliance; Group I), dead soft 8-braided (Bond-A-Braid, Reliance; Group II), or 5-stranded (PentaOne, Masel; Group III) LR wire. A control group consisting of people with a healthy periodontal condition and no bone loss was included (Control; Group C). The mobility of the lower anterior teeth on the right and left sides was measured using a Periotest® device before (T0), immediately after (T1), and 10 months after (T2) the application of the LR. Statistical analyses were performed using one-way ANOVA followed by post hoc LSD, repeated ANOVA with Bonferroni post hoc test, and Pearson χ2 tests.

Sex

All

Ages

14 to 20 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Successful completion of orthodontic treatment with optimum oral hygiene
  • A duration of orthodontic treatment with fixed appliances of more than 12 months
  • No missing teeth, restorations, or morphological crown anomalies
  • No radiological alveolar bone loss in the mandibular inter-canine region.

Exclusion criteria

  • Individuals with periodontal problems, such as gingival bleeding and recession, parafunctional habits (e.g., clenching and grinding),
  • Any radiological pathology around the lower anterior teeth

Trial design

0 participants in 4 patient groups

Group 1
Description:
Group 1 (n = 31), which contained patients fitted with 0.038 × 0.016" stainless steel wire (Ortho FlexTech® chain, Reliance Orthodontic Products, Itasca, IL, USA)
Treatment:
Other: measuring tooth stability after orthodontic treatment using a Periotest® device.
Group 2
Description:
Group 2 (n = 23), which contained patients fitted with 0.010 × 0.026" 8-braided dead soft wire (Bond-A-Braid,Reliance Orthodontic Products, Itasca, IL, USA)
Treatment:
Other: measuring tooth stability after orthodontic treatment using a Periotest® device.
Group 3
Description:
Group 3 (n = 28), which contained patients fitted with 0.0215" 5-stranded stainless steel wire (Penta-One®, Masel Orthodontics, Carlsbad, CA, USA)
Treatment:
Other: measuring tooth stability after orthodontic treatment using a Periotest® device.
Control group
Description:
Control group (n = 20), which contained individuals who had not received any orthodontic treatment
Treatment:
Other: measuring tooth stability after orthodontic treatment using a Periotest® device.