ClinicalTrials.Veeva

Menu

Effect of Different VV ECMO Flows on Lung Perfusion Monitored by EIT

H

Huazhong University of Science and Technology

Status

Enrolling

Conditions

Critical Illness

Study type

Observational

Funder types

Other

Identifiers

NCT05778292
ECMO20221119

Details and patient eligibility

About

The purpose of this study is to investigate the feasibility of using electric impedance tomography (EIT) to monitor lung perfusion during veno-venous (VV) extracopreal membrane oxygenation (ECMO) support, as well as the effect of different ECMO flows on lung perfusion monitored by EIT.

Full description

This is a monocentric obsevensional study that uses EIT to monitor lung perfusion during VV ECMO support and the effect of different ECMO flows on lung perfusion as measured by EIT. Patients on VV ECMO who meet the withdrawal criteria as determined by clinical experts will have their ECMO flow gradually reduced. EIT lung ventilation and perfusion monitoring were performed at various ECMO flows.

Enrollment

15 estimated patients

Sex

All

Ages

18 to 70 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Patients aged ≥ 18 and ≤ 70 years;
  2. Patients supported with VV ECMO for respiratory failure;
  3. Patients are intubated and mechanically ventilated.

Exclusion criteria

  1. EIT contraindications such as chest wound dressing, pacemaker installation, defibrillator, etc;
  2. Patients who did not sign the informed consent form;
  3. Pulmonary embolism;
  4. Pneumothorax;
  5. Medium to plenty of chest water;
  6. Atrial fibrillation or other malignant arrhythmia leads to a decrease in cardiac output;
  7. Refractory shock;
  8. Severe chronic heart and lung disease has existed in the past;
  9. BMI>35 kg/m2;
  10. Intra-abdominal pressure >20mmHg.

Trial contacts and locations

1

Loading...

Central trial contact

Xiaobo Yang, prof.; You Shang, prof.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems