ClinicalTrials.Veeva

Menu

Effect of Force Magnitude on Canine Retraction and Gingival Crevicular Fluid Proteome

U

UConn Health

Status

Enrolling

Conditions

Tooth Crowding

Treatments

Device: Heavy Force (400 g Niti coil)
Device: Light Force (150g Niti Coil)

Study type

Interventional

Funder types

Other

Identifiers

NCT06668194
22-314-2

Details and patient eligibility

About

This study aims to examine the effect of force levels in orthodontic treatment during canine retraction. Force levels refer to the pressure applied by the orthodontic devices to move teeth. Data collection will include gingival fluid, dental molds from a digital scanner, and x-rays of the upper canine region on both sides of the mouth during treatment. The null hypothesis to be tested is that there is no significant difference in the rate of canine movement between the light force and the heavy force levels.

Full description

Patients' participation in the study at the first visit (T0) Timepoint 0, will be started at the stage of canine retraction. At this appointment, 0.019 x 0.025-inch stainless steel archwire will be placed; power arms will be fabricated from 17x25-inch stainless steel on the maxillary first molars and canines. The height of the power arm will be matched with the center of resistance of both canines and molars based on the root length measured on the periapical radiographs. The archwire will be engaged in the canine bracket using stainless steel ligature wire.

At the T0 appointment, before applying the retraction force, periapical radiographs of canines (with coronal and apical reference wires for calibration and magnification correction) and GCF (gingival crevicular fluid) samples of each canine will be collected. Gingival sulcus of mesial and distal to canine (bilaterally) will be chosen as sites for GCF sample collection. The study coordinator will take a digital scan using iTero® Element™ in the clinic as the baseline (T0). As the split-mouth design will be applied in this study, right and left sides will be assigned randomly for either 150gm (light force) or 400gm force (heavy force) for each subject. NiTi coil spring calibrated for force magnitude at oral temperature will be used to deliver the assigned force will be engaged from the first molars to the canine power arms. IRB-approved written instructions will also be provided to all the participants. Follow-up visits will be scheduled. After applying the force, follow-up visits will be scheduled at (T1) 1-2 weeks, (T2) 4-5 weeks, (T3) 8-9 weeks, (T4)12-13 weeks, and (T5)16-17 weeks. A new digital scan will be taken at each study appointment (T0 - T5). These digital scans will be used for tooth movement measurements. GCF samples (mesial and distal to canines bilaterally) will be collected only for the first 3 appointments (T0 - T2) for the first 10 participants only in this study.

Periapical radiographs for canines on both sides will be obtained on (T0) Timepoint 0, and (T3) 8-9 weeks and (T5) 16-17 weeks of the study for each participant and analyzed to measure the EARR (external apical root resorption). Following the last study visit, all subjects' treatment will continue as recommended by the primary orthodontic care provider. No new data will be reviewed or collected after (T5).

Enrollment

40 estimated patients

Sex

All

Ages

11 to 16 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Healthy patient, non-smoker
  • Age: 11 - 16 years of age, inclusive.
  • A full complement of dentition (central incisor to 1st molar) in the four quadrants, except second molars
  • Patients requiring at least upper bilaterally maxillary 1st premolar extraction as a treatment plan (Class I bimaxillary protrusion/ crowding or Class II maxillary dentoalveolar protrusion/ crowding)
  • At least 5 mm of space left between canine and 2nd premolar to be closed at the time of canine retraction
  • At least six months after the extraction of first premolars and in a 0.019 x 0.025-inch stainless steel archwire in the maxilla
  • The ability to read and understand English and to provide informed consent

Exclusion criteria

  • Patients under 11 years of age and over the age of 16.
  • Non-extraction treatment plan
  • Extraction of maxillary tooth other than first premolars bilaterally.
  • Evidence of poor oral hygiene
  • Evidence of previous root resorption
  • Missing or impacted tooth in any of the quadrant except 3rd molars.
  • Medical issues that affect tooth movement
  • Inability to provide oral and written consent to participate.
  • Patient on medications that may alter bone metabolisms like bisphosphonates, oral contraceptives, or PTH (parathyroid hormone)
  • Chronic illness or syndromic patients.
  • Pregnant women, prisoners, and decisional impaired

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Single Group Assignment

Masking

Triple Blind

40 participants in 2 patient groups

Light force (150g Niti Coil Spring)
Active Comparator group
Description:
One of the maxillary canines to be retracted will be assigned to the light force group randomly. Patients' participation in the study (T0) will be started at the stage of canine retraction. At this appointment, 0.019 x 0.025-inch stainless steel archwire will be placed; power arms will be fabricated from 17x25-inch stainless steel on the maxillary first molars and canines. The height of the power arm will be matched with the center of resistance of both canines and molars based on the root length measured on the periapical radiographs. The archwire will be engaged in the canine bracket using stainless steel ligature wire. NiTi coil spring calibrated for force magnitude (150g) at oral temperature will be used to deliver the assigned force will be engaged from the first molars to the canine power arms.
Treatment:
Device: Light Force (150g Niti Coil)
Heavy force (400g NiTi Coil Spring)
Experimental group
Description:
One side of the maxillary canines to be retracted will have a heavy force assigned randomly. Patients' participation in the study (T0) will be started at the stage of canine retraction. At this appointment, 0.019 x 0.025-inch stainless steel archwire will be placed; power arms will be fabricated from 17x25-inch stainless steel on the maxillary first molars and canines. The height of the power arm will be matched with the center of resistance of both canines and molars based on the root length measured on the periapical radiographs. The archwire will be engaged in the canine bracket using stainless steel ligature wire. NiTi coil spring calibrated for force magnitude (400g) at oral temperature will be used to deliver the assigned force will be engaged from the first molars to the canine power arms.
Treatment:
Device: Heavy Force (400 g Niti coil)

Trial contacts and locations

1

Loading...

Central trial contact

Georgiana Defilio; Flavio Uribe, DDS, MDentSc

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems