ClinicalTrials.Veeva

Menu

Effect of Novel Exhalational Delivery System with Fluticasone (EDS-FLU) on Eustachian Tube Dysfunction (ETD)

Cedars-Sinai Medical Center logo

Cedars-Sinai Medical Center

Status and phase

Enrolling
Phase 2

Conditions

Eustachian Tube Dysfunction

Treatments

Drug: Fluticasone Propionate 93 MCG/1 ACTUATION Nasal Spray
Other: Placebo Nasal Spray

Study type

Interventional

Funder types

Other

Identifiers

NCT05275686
IIT-WU-2021-EuPEN

Details and patient eligibility

About

Intranasal nasal steroid sprays are the mainstay of treatment for chronic Eustachian tube dysfunction despite having little supportive evidence in the literature. A novel, commercially available nasal spray delivery system is available now for fluticasone that improves its delivery to the nasopharynx. The hypothesis of this study is that fluticasone using the novel spray system is effective for Eustachian tube dysfunction (ETD).

Full description

BACKGROUND AND RATIONALE

Eustachian tube dysfunction (ETD) can be a symptom of allergic rhinitis, non-allergic rhinitis, or chronic rhinosinusitis. However, it can also be a separate entity with patients displaying no other symptoms of the previously mentioned diseases. There is currently no FDA- approved medication specifically for eustachian tube dysfunction, but most otolaryngologists, allergists, and primary care physicians employ multiple different over-the-counter and prescription medications for its treatment. Most common are oral and topical antihistamines, nasal steroid sprays, topical and oral decongestants, and oral steroids. Nasal steroid sprays, which are FDA-approved for allergic rhinitis, are most frequently used for chronic ETD despite a lack of large clinical trials to support their use. These sprays do have good safety profiles, are frequently available over-the-counter, and do have good data on their efficacy in rhinitis and sinusitis.

Fluticasone nasal spray is available over the counter and is a nasal steroid spray. It is frequently recommended or prescribed for chronic eustachian tube dysfunction. However, its efficacy and the efficacy of all nasal sprays may be limited by the access of previously available sprays into the nasopharynx. The level of evidence for these sprays in chronic ETD is poor overall with only one randomized controlled trial in adults. This study determined no benefit over placebo. In studies determining the deposition of nasal sprays, most of the spray is deposited in the front of the nasal cavity over the inferior turbinates and very little gets into the sinus cavities or nasopharynx. A new exhalational delivery system fluticasone spray (EDS-FLU) has been FDA-approved for patients with chronic rhinosinusitis with polyps. The main difference between this spray and previously available sprays is that it penetrates deeper into the sinuses and also to the nasopharynx, the location of the eustachian tubes. In this system, the user blows out while pumping the spray bottle and his/her breath is the driving force of the spray bottle. Blowing out also elevates the soft palate, seals the nasopharynx, and contains all the spray into the nasal cavity, sinuses, and nasopharynx. In a traditional spray, the soft palate is at resting position, and the spray can pass through the nasal cavity and down into the oropharynx and mouth. This is typically perceived by many users as postnasal drip after the use of nasal sprays. The investigators have previously published a retrospective review of the use of EDS-FLU in patients with at least 1 month of ETD symptoms and found that 79% had improvement more than the minimal clinically important difference. Thirty-six percent of patients normalized with regards to symptoms, and 80% of patients with pre- and post-treatment tympanometry normalized their tympanogram. This study will compare placebo to fluticasone exhalational nasal spray system (Xhance) in a randomized, controlled study.

Enrollment

80 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Age greater than or equal to 18 years old, <80 years old

  • Chronic Eustachian tube dysfunction defined as:

    • Symptoms in one or both ears > 3 months AND
    • ETDQ-7 score >14.5 AND
    • Type B, C, or As tympanometry
  • Female subjects of childbearing potential must have a negative urine pregnancy test at screening and throughout the study duration.

Exclusion criteria

  • Age <18 years old
  • Known history of otologic surgery (excluding myringotomy or myringotomy tubes)
  • Use of any additional intranasal medication
  • Tympanic membrane perforation
  • Adhesive otitis media
  • Cholesteatoma or significant retraction pocket
  • Middle ear effusion
  • Nasopharyngeal tumor
  • Any history of head and neck cancer
  • Any history of head and neck irradiation
  • Any history of temporomandibular disorder or prior surgery to the temporomandibular joint
  • Any medical condition that the investigator deems inappropriate for enrollment

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

80 participants in 2 patient groups, including a placebo group

Arm 1 (Placebo)
Placebo Comparator group
Description:
Arm 1 (placebo) will get placebo spray per day.
Treatment:
Other: Placebo Nasal Spray
Arm 2 (EDS-FLU)
Active Comparator group
Description:
Arm 2 (EDS-FLU) will get 744 mcg of fluticasone propionate per day.
Treatment:
Drug: Fluticasone Propionate 93 MCG/1 ACTUATION Nasal Spray

Trial contacts and locations

4

Loading...

Central trial contact

Missael Vasquez; Laura Sarmiento, CCRP

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems