Effect of Passive Leg Raising for Fluid Responsiveness

M

Medical University of Warsaw

Status

Unknown

Conditions

Impedance
Cardiac Output, Low
Body Fluid Retention

Treatments

Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis

Study type

Interventional

Funder types

Other

Identifiers

NCT02702544
02.014.1MR

Details and patient eligibility

About

Changes in volumetric hemodynamic parameters and fluid overload (Cardiac Index,Stroke Volume, Thoracic Fluid Content, Systemic Vascular Resistance) were measured using a impedance cardiography (ICG) (CardioScreen 1000 - Haemodynamic Measurement System, Medis. GmbH Ilmenau) while lifting the leg at different angles. The measurement lasted 12 minutes.

Enrollment

80 estimated patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • give voluntary consent to participate in the study
  • no clinical cardiovascular disease during the 6 months proceeding entry

Exclusion criteria

  • not meet above criteria
  • episode of illness (for example: infection)
  • pregnancy

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

80 participants in 5 patient groups

neutral position
Experimental group
Description:
the patient is in the neutral position, located on his back on a flat surface
Treatment:
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis
Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System
legs raised for 20 degrees
Experimental group
Description:
patient is placed on a flat surface, legs raised for 20 degrees, supported around ankles
Treatment:
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis
Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System
legs raised for 30 degrees
Experimental group
Description:
patient is placed on a flat surface, legs raised for 30 degrees, supported around ankles
Treatment:
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis
Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System
legs raised for 45 degrees
Experimental group
Description:
patient is placed on a flat surface, legs raised for 45 degrees, supported around ankles
Treatment:
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis
Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System
legs raised for 60 degrees
Experimental group
Description:
patient is placed on a flat surface, legs raised for 60 degrees, supported around ankles
Treatment:
Device: CardioScreen 1000 - Haemodynamic Measurement System, Medis
Device: SCHILLER, BR-102 plus - Ambulatory Blood Pressure Monitoring System