ClinicalTrials.Veeva

Menu

Effect of Pressure Regulation on Optic Nerve Sheath Diameter

K

Keimyung University

Status

Completed

Conditions

Optic Nerve Sheath Diameter

Treatments

Other: RALRP under lower mean BP

Study type

Interventional

Funder types

Other

Identifiers

NCT04339244
2019-07-049

Details and patient eligibility

About

Intracranial pressure is known to increase during robot-assisted laparoscopic radical prostatectomy (RALRP) due to steep trendelenberg position. Measurement of optic nerve sheath diameter (ONSD) is a indirect method which can assess the degree of intracranial pressure.

This study is designed to measure the ONSD during RALRP under regulation of arterial pressure.

Full description

During last decades, RALRP has been advocated due to the advantages of short hospital stay, reduced blood loss during surgery, less postoperative pain and complication. During RALRP, steep trendelenberg postion and pneumoperitoneum are required essentially, and this is for the acquisition of adequite surgical field. However, such position and pneumoperitoneum can result in harmful hemodynamic change. Previous study demonstrated that patients of RALRP showed 12.5% increase of ONSD.

The relationship of ONSD and increase of intracranial pressure has been proved previously through many studies. Recent meta analysis showed that ONSD measurement for the monitor of ICP demonstrated that sensitivity 0.9, specificity 0.85 and ROC cuve 0.983.

In addition, increase of ONSD during RALRP can be affected by the degree of arterial pressure and end tidal CO2 increase.

This study is designed to see the effect of arterial pressure regulation on the increase of ONSD

Enrollment

51 patients

Sex

All

Ages

30 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Prostate cancer receiving RALRP

Exclusion criteria

  • glaucoma
  • intracranial tumor
  • previous disease elevating intracranial pressure

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

51 participants in 2 patient groups

ONSD measurement under lower blood pressure
Active Comparator group
Description:
ONSD measurement under mean blood pressure of 60\~70 mmHg
Treatment:
Other: RALRP under lower mean BP
Other: RALRP under lower mean BP
ONSD measurement under highly normal blood pressure
Active Comparator group
Description:
ONSD measurement under mean blood pressure of 90\~100 mmHg
Treatment:
Other: RALRP under lower mean BP
Other: RALRP under lower mean BP