Effect of Scanning Techniques on Accuracy of Mandibular Fixed Detachable Prostheses

T

Tanta University

Status

Enrolling

Conditions

Full Arch Implant Rehabilitation

Treatments

Device: IO Connect Scanning Technique
Device: Splinted Scan Body with composite
Device: Auxiliary Geometric Device Scanning Technique

Study type

Interventional

Funder types

Other

Identifiers

NCT07740265
RP-11-25-3482

Details and patient eligibility

About

This crossover clinical study aims to evaluate the influence of three different intraoral scanning techniques on the scanning accuracy and passive fit of mandibular implant-supported fixed detachable prostheses in completely edentulous patients. Each participant will undergo digital implant scanning using three methods: splinted scan bodies, horizontal non-calibrated scan bodies (IO Connect), and auxiliary geometric devices.

Full description

This prospective crossover clinical trial is designed to evaluate and compare the accuracy and passive fit of three different intraoral scanning techniques used for the fabrication of mandibular implant-supported fixed detachable prostheses in completely edentulous patients.

The study will include completely edentulous participants rehabilitated with four osseointegrated implants placed in the mandibular arch. Each participant will undergo digital implant impression procedures using three different scanning .

The three scanning techniques being compared are:

  1. Splinted Scan Bodies: Implant scan bodies will be splinted using composite resin before intraoral scanning.
  2. Horizontal Non-Calibrated Scan Bodies (IO Connect): Digital impressions will be obtained using the IO Connect horizontal scan body system.
  3. Auxiliary Geometric Devices: Digital impressions will be acquired using 3D-printed auxiliary geometric devices attached to the scan bodies to provide additional geometric reference landmarks during scanning.

Digital datasets generated from each scanning technique will be analyzed and compared. Verification jigs will be fabricated using CAD/CAM technology and clinically evaluated.

The primary outcomes of the study are scanning accuracy, assessed by measuring linear deviation (µm) and angular deviation (degrees) between implant positions obtained from the different scanning techniques, and three-dimensional surface deviation analysis, assessed through root mean square (RMS) values and median surface deviation obtained from STL file superimposition.

The secondary outcome is passive fit , which will be evaluated using the Sheffield one-screw test and intraoral periapical radiographic assessment.

The findings of this study will help identify the scanning technique that provides the highest accuracy and best passive fit for mandibular implant-supported fixed detachable prostheses and may contribute to improving digital workflows in complete-arch implant rehabilitation.

Enrollment

7 estimated patients

Sex

All

Ages

40 to 60 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Completely edentulous patients with age between 40-60 years.
  • Adequate bone height to fulfill the criteria for implant placement.
  • Patients should have a class I Angle's classification.

Exclusion criteria

.Insufficient vertical inter-arch space to accommodate the restorative components.

.Presence of psychiatric or neurological conditions. .Any systemic diseases that may affect implant bone osteointegration.

Trial design

Primary purpose

Device Feasibility

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

7 participants in 3 patient groups

Splinted Scan Bodies with composite
Experimental group
Description:
Participants will undergo full-arch digital implant scanning using implant scan bodies splinted with composite resin. The splinting procedure is intended to improve the stability of scan bodies and reduce positional discrepancies during digital impression acquisition.
Treatment:
Device: Splinted Scan Body with composite
horizontal non-calibrated scan bodies
Experimental group
Description:
Participants will undergo full-arch digital implant scanning using horizontal non-calibrated scan bodies (IO Connect). This technique utilizes a horizontal scan body design to facilitate implant position recognition, digital alignment, and complete-arch digital impression acquisition.
Treatment:
Device: IO Connect Scanning Technique
Auxiliary Geometric Device Scanning
Experimental group
Description:
Participants will undergo full-arch digital implant scanning using 3D-printed auxiliary geometric devices attached to implant scan bodies. The auxiliary devices provide additional geometric reference landmarks intended to improve scanning accuracy and reduce stitching errors during complete-arch digital impressions.
Treatment:
Device: Auxiliary Geometric Device Scanning Technique

Trial contacts and locations

1

Loading...

Central trial contact

Mostafa Hamed Mostafa Abd El-Hameed Abd El-Hameed, BDS, MSc

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems