ClinicalTrials.Veeva

Menu

Effect of the Minimum Bronchial Cuff Volume of Left-sided Double-lumen Endotracheal Tube for One-lung Ventilation on the Change of the Bronchial Cuff Pressure During Lateral Positioning in Thoracic Surgery

K

Kyungpook National University Chilgok Hospital

Status

Completed

Conditions

Pneumothorax
Lung Cancer

Treatments

Device: Cuff pressure measurement
Behavioral: Lateral positioning

Study type

Observational

Funder types

Other

Identifiers

NCT05222568
KNUCH 2021-08-059-001

Details and patient eligibility

About

Over-inflation of the bronchial cuff of the double-lumen tube (DLT) can cause damage to the airway mucosa and misplacement of the tube, and under-inflation may cause incomplete collapse of the non-ventilated lung and incomplete ventilation of the lung that should be ventilated. Appropriate cuff pressure is generally known to be ranged 20-30 cmH₂O, but in the study of Okubo et al., who observed the minimum bronchial cuff volume and pressure that did not cause air leakage using the method of confirming by capnography, it was possible to obtain the result that OLV was possible without air leakage even at a pressure lower than 25 cmH₂O (the generally recommended tube cuff pressure) in both men and women. In a recent study of Yamada et al., when using the capnography waveform-guided method to inflate the bronchial cuff by checking for air leakage using the capnography waveform, the bronchial cuff volume (BCV) that satisfies the air-tight seal was significantly smaller compared with a pressure-guided method to inflate the bronchial cuff with 20 cmH₂O.

The minimum bronchial cuff volume (BCVmin) at which such air leakage does not occur may vary from individual to individual. It is presumed that this is because the diameter of the left main bronchus (LMB) differs from individual to individual, which causes the variation of the gap between the diameter of the LMB and the outer diameter of the DLT mounted thereon. Moreover, the previous study revealed that the lateral positioning could increase the pressure of the bronchial cuff mounted on the LMB due to the gravity-induced morphological and conformational change of the trachea. Considering these factors, the researchers hypothesized that the change in the bronchial cuff pressure (BCP) due to a positional change might vary depending on whether the bronchial cuff was inflated, that is, the initially established BCVmin.

Therefore, in this study, the researchers tried to investigate the effect of BCVmin on the change of minimum bronchial cuff pressure (BCPmin) due to the positional change from the supine to lateral decubitus, by dividing the groups whose BCVmin is 0 ml or exceeds 0 ml.

Enrollment

70 patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Patients aged 18-80 and with an American Society of Anesthesiologists (ASA) physical status of 1 or 3 who are scheduled to undergo elective video-assisted thoracoscopic surgery (VATS)

Exclusion criteria

A. Need for a right-sided DLT B. An intraluminal lesion in the left main bronchus C. An anatomical problem in the tracheobronchial tree D. Patients with chronic obstructive pulmonary disease with impaired lung compliance E. Patients with interstitial lung disease with severe pulmonary dysfunction F. Patients with Body mass index (BMI) ≥ 30

Trial design

70 participants in 2 patient groups

BCVmin=0
Description:
This study was a prospective observational study, and the patients was divided into two groups with BCVmin=0 or BCVmin \>0, according to the BCVmin which was naturally determined during anesthesia in each patient.
Treatment:
Device: Cuff pressure measurement
Behavioral: Lateral positioning
BCVmin>0
Description:
The patients was divided into two groups with BCVmin=0 or BCVmin \>0, according to the BCVmin which was naturally determined during anesthesia in each patient.
Treatment:
Device: Cuff pressure measurement
Behavioral: Lateral positioning

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems