Status
Conditions
Treatments
About
In this randomised placebo-controlled trial, the investigators will include 30 PD (Parkinson's disease) patients with HY (Hoehn Yahr stage) >2 and L-dopa unresponsive gait characteristics. Each participant will receive taVNS at 25Hz, taVNS at 100Hz and sham VNS (sVNS). During each stimulation, different gait characteristics will be measured with wearable insertion motion sensors.
Full description
Participants and study overview:
In this randomised placebo-controlled trial, the investigators will include 30 PD patients with HY>2 and L-dopa unresponsive gait characteristics. Each participant will complete 1 visit, during which the instrumented stand and walk test will be repeated 16 times. The baseline measurement will be followed by three different stimulation conditions sham VNS (sVNS), taVNS at 25Hz (taVNS25) and taVNS a 100Hz (taVNS100). sVNS, taVNS25 and taVNS100 in a randomized order. To enhance gait disturbances, the participants will perform iSAW during each condition twice in silence and twice while simultaneously performing calculations around.
Instrumented stand and walk test (iSAW):
To perform iSAW, participants will first stand still for 30s, after which they will start walking in a straight line for 7m, turn and walk back to the start. The participants will be equipped with 6 inertion Opal ® motion sensors (on both feet, both wrists, on the lumbar back and on their sternum). For the laud counting iSAW condition (iSAW-C), the participants will perform iSAW as described above while also counting backwards by 3 from numbers above 100.
TaVNS:
Noninvasive electrostimulation will be applied to the left ear. taVNS will be applied to the cyma conchae and sVNS will be applied to the earlobe. Both taVNS and sVNS were applied through the Nemos® electrode with the following parameters: square-shaped pseudobiphasic pulse, interpulse duration 80μs, pulse width 300μs, pulse intensity 0,1mA above the perceptual threshold (figure 1). taVNS25 and sVNS will be applied at 25Hz and taVNS100 will be applied at 100Hz. The intensity for each separate stimulation will be adjusted for each participant at the beginning of the experiment. For each condition, the electrode will be placed in the ear by a third person and the ear will be covered by cotton pads and an EEG cap to hide the electrode position from the experimenter. The order of stimulation will not be revealed until the automated data and statistical analysis.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
30 participants in 4 patient groups
Loading...
Central trial contact
Vesna M van Midden, MD
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal