Status
Conditions
Treatments
Study type
Funder types
Identifiers
About
The aim of this study is to determine the effect of vibration anesthesia on injection pain, ecchymosis and comfort level in subcutaneous heparin injection.This study was conducted in a randomized controlled experimental design.
Full description
Population and Sample of the Research
The population of the research consisted of the doses administered by subcutaneous heparin injection in the chest diseases clinic of Atatürk University Health Research and Application Center. Among the total data related to the study, 162 patients were evaluated. There were 28 patients who met the study eligibility criteria and 18 who refused to participate in its terms. 116 patients who volunteered to comply with the data collection, total fee criteria and participate will be assigned to the experimental group, 58 patients to the control group, and 58 patients to the control group by randomization. 8 patients from the experimental group left the study because they were discharged early. In the control group, 6 patients were discharged early rather than 2 patients in the study. Training data was completed with 50 patients in both experimental and control classes. To determine whether the sample size was sufficient, post-hoc power analysis was calculated with the G*Power 3.1.9.7 program.
Post hoc power analysis of the study was determined to be over 0.90 with a margin of error of 0.05 for the analysis conducted on the basis of t test in independent groups of the 2nd combination application. Completed with 50 patients in both the experimental and control groups. Post-hoc power analysis was calculated with the G*Power 3.1.9.7 program to determine whether the sample size was sufficient. The power of the study was determined to be above 0.90 with a margin of error of 0.05 for the post hoc power analysis based on the t test in independent groups for the 2nd injection application.
Inclusion Criteria
Non-reception Criteria
Exclusion Criteria
Data Collection Tools:
The data of the study will be collected using 4 forms. Patient Introduction Form, Octoberosis Measurement Tool, Visual Analog Scale, Visual Analog Comfort Scale, Patient Follow-up Form will be used.
Patient Introduction Form It is a form prepared in line with the literature that includes the information of the patients (gender, age, marital status, educational status, employment status, body mass index, chronic disease, continuous medication use, smoking status).
Ecchymosis Measurement Tool A transparent measuring tool was used to measure the ecchymosis at the injection site. The transparent measuring tool was placed on the ecchymosis and the borders of the ecchymosis were drawn with an acetate pen; then, the size of the ecchymosis was determined in mm2 by placing the transparent measuring tool on a millimeter measuring paper and recorded on the patient follow-up form. The size of the ecchymosis was measured at 48 hours after injection. It is reported that ecchymosis after subcutaneous heparin injection is most prominent after 48 hours . Based on the literature, discoloration smaller than 2 mm2 was considered as "no ecchymosis", and the size of discoloration of 2 mm2 or more was measured.
Visual Analog Pain Scale The Visual Analog Scale (VAS) is a scale system used to convert some characteristics that cannot be quantitatively measured into numerical values. VAS pain was used to measure the intensity of pain during injection. The VAS pain scale is expressed as "0=No pain, 10=Unbearable pain" on a 10 cm horizontal line. Patients were asked to mark the intensity of pain experienced during subcutaneous injection with an X on the scale. It is a widely used valid scale.
Visual Analog Comfort Scale The VAS comfort is a 10 cm long horizontal measurement tool that starts with "most comfortable" and ends with "most uncomfortable". Patients rated their comfort level with this scale. For a better understanding of the term comfort by patients, they were asked to indicate their "comfort, satisfaction or level of comfort with the injection" on the scale. It is a valid scale widely used to assess comfort.
Patient Follow-up Form The patient follow-up form records the date and time of the injection, the patient's name or pseudonym, the group to which the patient belongs, the standard injection method with or without vibration, the injection site, pain intensity, comfort level and ecchymosis size.
Vibration Anesthesia Device The vibration anesthesia device is a reusable, handheld device with a battery-powered motor and a vibration frequency of approximately 6000 times per minute. Based on the Gate Control Theory, one of the pain theories, vibration anesthesia is used to reduce pain in injections . The vibration anesthesia device helps to close the pain gate by stimulating large diameter nerve fibers during the application. By producing low-frequency vibrations, the device affects the nerves under the skin and prevents pain signals from reaching the brain.
Standard Subcutaneous Heparin Injection without Vibration The steps of injection are given below.
Vibratory Subcutaneous Heparin Injection Steps 1-6 were performed as in standard subcutaneous heparin injection without vibration. The vibration anesthesia device was wiped with 70% alcohol cotton wool and allowed to dry. The researcher held the vibration anesthesia device for 3 minutes on the exact injection point just before the injection. Immediately afterwards, the skin and subcutaneous tissue were grasped and subcutaneous injection was performed according to steps 7-17 of the standard subcutaneous heparin injection.
Data Collection Patients were informed about the study and their consent was obtained. Before the injection, the patients were informed that they would be asked about the severity of pain they felt after the injection and their comfort level. Platelet, PTZ, aPTT, aPTT, INR values determined in the last 24 hours were checked. The abdomen was chosen as the injection site in the study. Since muscle movements are less in the abdomen, patient-specific differences may be less in the follow-up of ecchymosis after injection compared to the arm and leg. Another reason for choosing the abdominal region is that clinical nurses mostly prefer the arm and leg regions for heparin injections outside the study. The abdominal region of the patient was evaluated for incision, infection, ecchymosis and/or hematoma, and scar tissue. All injections in the experimental and control groups were performed by the same investigator. Patients and clinic nurses were informed not to perform another injection in the injection site and not to wash the injection site for 48 hours for ecchymosis follow-up.
Experimental Group The patients in the experimental group were administered subcutaneous heparin injections with and without vibration, the order of which was determined by lottery, at one day intervals. The purpose of administering two injections with and without vibration to the experimental group was to obtain control data within the experimental group by controlling individual factors related to the dependent variables of the study. The non-vibrated injection was performed according to the standard subcutaneous heparin injection steps. For vibratory injection, vibration anesthesia was applied to the injection site for three minutes just before the procedure , followed by standard injection steps. The right and left sides of the lower abdomen were randomly used as the injection site. The injection site was circled with an acetate pen.
Control Group In the control group, two non-vibrated SC heparin injections were administered 24 hours apart. The aim of administering two non-vibrated injections to the control group was to obtain control data within the control group by controlling individual factors related to the dependent variables of the study. In the control group, injections were performed according to the steps of standard subcutaneous heparin injection without vibration. The right and left sides of the lower abdomen were randomly used as the injection site. The injection site was circled with an acetate pen.
Randomization Randomization was performed in a computerized environment using the website https://www.randomizer.org/web. In randomization, each patient was assigned to only one group with a 1:1 chance of selection. Randomization was performed by a statistical expert who was not involved in the research process. According to the randomization outputs, patients' numbers were listed in two groups. The lottery method was used to determine the two groups as experimental and control groups. The first group drawn first was assigned to the experimental group and the second group drawn second was assigned to the control group. Patients who met the inclusion criteria were numbered according to the order of hospitalization. Patients were identified as being in the experimental or control group according to their numbers.
The order of the non-vibratory and vibratory standard injections administered to the patients in the experimental group was determined randomly by lottery method. Injection methods were coded as A and B. The researcher wrote the names of the injection methods on two pieces of paper and drew lots to determine which injection would be coded A and B. The first method drawn was vibratory injection: A and the second method drawn was non-vibratory injection: B. The injection order was classified as AB, BA. Then, for each patient, which of the AB or BA injection order would be chosen was determined by lottery.
Another method used to prevent bias in experimental studies is blinding. The main purpose of blinding is to obtain and evaluate the results objectively. Patients were not informed that they were in the experimental or control group. Patients were blind to the hypotheses of the study. During the data analysis phase, the experimental group was coded as A and the control group as B, and the statistician was blinded to the study.
This randomized controlled experimental study was conducted according to "The CONSORT-Outcomes 2022 Extension guidelines.
Data Evaluation Data were analyzed with the SPSS for Windows 22 software package . Continuous data were presented as mean ± standard deviation and categorical data were presented as frequency and percentage. Chi-square test was used to compare categorical demographic data between groups. Kurtosis and skewness values in the range of ±2 indicate that continuous variables are normally distributed . It was determined that ecchymosis size was not normally distributed in the experimental and control groups, while other variables were normally distributed. In intergroup comparison, independent samples t test was performed for normally distributed parameters and Mann Whitney U analysis was performed for non-normally distributed measurements. In intragroup comparison, paired sample t test was used for normally distributed parameters and Wilcoxon sign test was used for non-normally distributed parameters. In the study, p<0.05 was considered statistically significant. The effect size of the difference was calculated if a difference was found in intra- and inter-group comparisons. The effect size was classified as insignificant (0.0-0.19), low (0.20-0.49), moderate (0.50-0.79) and high effect (≥0.80).
Financial Source This research was supported by the Scientific Research Projects (BAP) Coordination Unit of Atatürk University Rectorate as project number TYL-2023-12968.
Enrollment
Sex
Ages
Volunteers
Inclusion and exclusion criteria
Inclusion Criteria
Non-reception Criteria
Exclusion Criteria
-The patient follow-up form records the date and time of the injection, the patient's name or pseudonym, the group to which the patient belongs, the standard injection method with or without vibration, the injection site, pain intensity, comfort level and ecchymosis size.
Primary purpose
Allocation
Interventional model
Masking
142 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal