Aim of the study is to evaluate the effects of vented base bottles on respiration-swallow patterns and on gastroesophageal refluxes in preterm infants with clinical suspect of gastroesophageal reflux disease (GERD).
In this crossover-randomized study, we compared the effects of standard feeding bottles (A) versus vented base feeding bottles (B) on a group of patients with at least 2 clinical GERD symptoms. 24 hours of synchronized cardiorespiratory (CR) and Esophageal Multichannel intraluminal impedance (MII/pH) monitoring were evaluated for each patient. During this period, patients were fed alternatively with feeding bottle A and B.
Full description
In preterm infants a deficit of both coordination and gastro-intestinal motility is often the underpinning cause of oxygen desaturations and gastro-esophageal reflux. Breastfeeding enhances the maturation of the respiration-swallow mechanism. For this reason, a feeding bottle that best recreates the physiological sucking from the maternal breast is highly desirable in non-breastfed newborns.
Population: newborns referred to esophageal Multichannel Intraluminal Impedance and pH-metry (MII/pH) combined with cardiorespiratory (CR) monitoring for GERD or cardio-respiratory symptoms
Materials and methods: we compare the effects of traditional feeding bottles (A) versus vented base feeding bottles (B) on cardiorespiratory and reflux events in newborns undergoing 24 hours synchronized CR and MII/pH monitoring. During the exam, newborns are fed, alternatively, by feeding bottle A and B with human milk or formula. Some training meals are offered the day before monitoring to get newborns enrolled into the study used to vented base feeding bottles.
Cardiorespiratory monitoring is performed through VitaGuard VG3100® (Getemed Medizin- und Informationstechnik AG, Teltow, Germany) based on Masimo Signal Extraction Technology (SET)® (Masimo Corp., Irvine, CA, USA). It operates with a blood oxygen saturation (SpO2) detector, placed on the right wrist, and 3 thoracic electrodes. This instrument is able to record ECG, heart rate, SpO2 and thoracic plethysmographic curve. The signals are analyzed with VitaWin 3® software (Getemed Medizin - und Informationstechnik AG, Teltow, Germany), by filtering artifacts.
The MII/pH monitoring is performed through a neonatal catheter (Infant Comfort TEC®) with 7 impedence electrodes (creating 6 impedance channels) and one pH detector able to cover the whole distance from the pharynx to the lower esophageal sphincter (LES) (channel 1). The pH detector is placed within channel 1, 1.5 cm above the LES. The correct positioning of the catheter is measured through fluoroscopy and eventually corrected. Data obtained from impedance channels that result proximal to the superior esophageal sphincter are excluded from the analysis. The acquisition and recording of MII/pH data are performed through Sleuth System, Sandhill Scientific Inc., Highlands Ranch, Colorado, USA. The analysis of MII/pH tracings is made visually by a single operator using BioView 5.3.4 software (Sleuth System, Sandhill Scientific Inc., Highlands Ranch, Colorado, USA).
The variables analyzed are listed as follows:
Clinical variables:
Cardiorespiratory variables:
MII/pH variables:
Randomization: the alternate use of feeding bottles A and B is set by a binary random sequencing generated by Microsoft Office Excel software that indicates the first feeding bottle to be used. This is a single-blind study since the sequence is unknown to the specialist in charge of reporting MII/pH and CR monitoring.
Statistical analysis:
The analysis is made with Statistical Software Package For Windows® (StatSoft, Inc., Tulsa, Oklahoma, USA). Kolmogorov-Smirnov test and exploratory data analysis are used to define normality range. Data will be expressed as mean and standard deviation (SD), or as median and interquartile range if more appropriate. Differences among cardiorespiratory and MII/pH variables will be evaluated with Student paired T test or Wilcoxon test if more appropriate. Significance will be considered as p<0.05.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
30 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal