Efficacy of Electrical Pudendal Nerve Stimulation for Patients With Post Prostatectomy Urinary Incontinence

S

Shanghai Institute of Acupuncture, Moxibustion and Meridian

Status

Completed

Conditions

Urinary Incontinence

Treatments

Device: PFM training
Device: Transanal ES
Device: Electrical pudendal nerve stimulation

Study type

Interventional

Funder types

Other

Identifiers

NCT02599831
ZYSNXD-CC

Details and patient eligibility

About

The purpose of this study is to determine whether electrical pudendal nerve stimulation is more effective than pelvic floor muscle training plus transanal electrical stimulation in treating post prostatectomy Incontinence.

Full description

Conservative therapy could be considered a choice of treatment for stress urinary incontinence (SUI) as it seems to have no side effect and causes significant and long-term improvement in symptoms. Pelvic floor muscle training (PFMT) and electrical stimulation are two commonly used forms of conservative treatment for SUI. PFMT improves the structural support of the pelvis. However, many patients have difficulty identifying and isolating their pelvic floor muscles (PFM) and are unable to perform the exercise effectively. Furthermore, patients who can identify the PFM often find that the required daily exercise routine is burdensome. Hence, the primary disadvantage of PFMT is lack of long-term patient compliance. Electrical stimulation (ES) is a non-invasive, passive treatment that produces a muscle contraction. Transanal electrical stimulation (TES) has little side-effect, and the patient compliance is 70-85% in published reports. TES results in PFM contraction by indirect nerve stimulation, mainly by polysynaptic reflex responses. The indirect stimulation and reflexive contraction may be the reason why the effect of electrical stimulation is not as good as that of PFMT when performed correctly. By combining the advantages of PFMT and TES and incorporating the technique of deep insertion of long acupuncture needles, we developed electrical pudendal nerve stimulation (EPNS). In EPNS, long acupuncture needles of 0.40 Х 100 or 125 mm were deeply inserted into four sacral points and electrified to stimulate the pudendal nerves (PN) and contract the PFM. CT transverse plane at the coccygeal apex has showed that the position of the lower needle tip is similar to where (adjacent to PN at Alcock's canal) the Bion device is implanted for chronic PN stimulation. Our previous study showed that EPNS had a better therapeutic effect on female SUI as compared with PFMT + TES. Simultaneous records of perineal ultrasonographic PFM contraction, vaginal pressure and pelvic floor surface electromyogram in our previous study have proved that EPNS can exactly excite PN and induce PFM contraction in female SUI patients. However, EPNS has also shown satisfactory effect in male patients with SUI problems. The purpose of this study is to compare the efficacy of EPNS to PFMT + TES in treating male SUI.

Enrollment

96 patients

Sex

Male

Ages

25 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • incontinence at 1 month or more after RP
  • ≥2 incontinence episodes a week on baseline 7-day bladder diary
  • no residual cancer after RP on pathological examination

Exclusion criteria

  • the presence of preoperative incontinence
  • treatment with anticholinergics
  • urinary tract infection or hematuria
  • postvoid residual volume>100 mL

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

96 participants in 2 patient groups

Electrical pudendal nerve stimulation
Experimental group
Description:
Four sacrococcygeal points were selected. Two 0.40Х100 mm needles were inserted perpendicularly to a depth of 80-90 mm 1 cm bilateral to the sacrococcygeal joint, to produce a sensation referred to the root of the penis (perineum) or the anus. Two needles of 0.40Х100 or 125mm were inserted obliquely toward the ischiorectal fossa to a depth of 90 to 110 mm about 1 cm bilateral to the tip of the coccyx, to produce a sensation referred to the root of the penis (or the perineum). Each two ipsilaterally needles were connected to one electrode from a G6805-2Multi-Purpose Health Device (Shanghai Medical Instruments High-Techno, Shanghai, China), with a frequency of 2.5 Hz and an intensity (45\~55 mA). EPNS was given for 60 min a time, 3 times per week for 8 weeks.
Treatment:
Device: Electrical pudendal nerve stimulation
PFM training with Transanal ES
Active Comparator group
Description:
Electromyogram BF-assisted PFMT (using a nerve function reconstruction treatment system (AM1000B; Shenzhen Creative Industry Co. Ltd, China) and following TES (using a neuromuscular stimulation therapy system (PHENIX USB4, Electronic Concept Lignon Innovation, France)) at a current intensity of \< 60 mA (as high as possible within the patient's tolerance) and frequencies of 15 Hz and 85 Hz (alternate 3-minute periods of stimulation) were performed by a specially trained therapist, 20 minutes each time, respectively (a total of 40 minutes), 3 times a week for a total of 8 weeks. The patients were also required to conduct 30 maximal high-intensity PFM contractions for 2-6 seconds (with 2-6 seconds rest), 3 sessions every day at home for a total of 8 weeks.
Treatment:
Device: Transanal ES
Device: PFM training