Electrode-Based Sensor for Non-Invasive Fetal Heart Rate Monitoring With Improved Reliability (FHR)

O

OBMedical Company

Status

Completed

Conditions

Laboring Women With Ultrasound and FSE Monitoring

Study type

Observational

Funder types

Other

Identifiers

NCT02024165
IRB (Other Identifier)
OBM-WP-2013

Details and patient eligibility

About

The specific goal of the proposed research is to develop a reliable, non-invasive fetal and maternal heart rate and contraction monitor that is unaffected by obesity and requires less nursing intervention than the tocodynamometer and Doppler ultrasound.

Full description

The majority of obstetric deliveries in the US undergo electronic monitoring and continuous uterine activity and fetal heart rate (FHR) monitoring is the standard of care. Typically, external transducers are employed, the reliability of which depends on their proper positioning, which may be disturbed by patient or fetal movement. The tocodynamometer (strain gauge, toco for short) provides frequency and timing of contractions, but requires transmission of tension from the uterus to the sensor. Fetal heart rate is acquired with an external Doppler ultrasound transducer. The reliability of this monitor depends on the ability to obtain a window to the fetal heart.

In some patients, particularly the obese, the toco and ultrasound may fail to monitor consistently. In others both transducers require frequent repositioning by the nursing staff, and the Doppler may erroneously report maternal heart rate instead of fetal.

The alternative uterine activity monitor is an intrauterine pressure catheter (IUPC), which is placed through the cervical os in the adequately dilated patient with ruptured membranes. While this monitor usually provides a more reliable signal than the toco, as well as quantitative information regarding intrauterine pressure, it is invasive and there is an increased risk of infection. The alternative FHR monitor is via fetal scalp electrode (FSE), which is applied transvaginally to the fetal presenting part, also requiring adequate cervical dilation and ruptured membranes. While the FSE usually provides a more reliable signal, it is similarly invasive and increases risk of infection.

Maternal obesity (defined as BMI at presentation ≥ 30) is an ever-increasing problem in the US, and is even more prominent in the obstetric suite. Meanwhile, obese women have an increased risk for labor problems, infections and other complications. Noninvasive labor monitoring, while preferable to reduce the infection risk, is particularly unreliable in this population.

Enrollment

71 patients

Sex

Female

Ages

18 to 50 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Parturients presenting to Labor & Delivery for labor at term (>36 weeks completed gestation)
  • Single viable fetus in cephalic presentation
  • With FSE or IUPC for obstetric indications

Exclusion criteria

  • Multi fetal gestation
  • Contraindication to FSE or IUPC placement
  • Insufficient abdominal space for all required sensors

Trial design

71 participants in 2 patient groups

Electrode Sensor, FSE
Description:
Pregnant women between the ages of 18-50 with a single viable fetus in cephalic presentation monitored with Electrode Sensor, and/or FSE
Electrode Sensor, Ultrasound
Description:
Pregnant women between the ages of 18-50 with a single viable fetus in cephalic presentation monitored with Electrode Sensor, and/or Ultrasound