ELEVATE-HFpEF Clinical Study

Medtronic logo

Medtronic

Status

Begins enrollment in 3 months

Conditions

Heart Failure With Preserved Ejection Fraction (HFpEF)

Treatments

Device: Personalized cardiac pacing

Study type

Interventional

Funder types

Industry

Identifiers

NCT06678841
MDT23039

Details and patient eligibility

About

ELEVATE-HFpEF is a prospective, randomized, controlled, double-blinded, multi-center, global, interventional pivotal study evaluating the safety and efficacy of dual chamber personalized pacing compared to minimal or no pacing for the treatment of patients with heart failure with preserved ejection fraction (HFpEF).

Full description

This study will evaluate a personalized cardiac pacing rate as a treatment for symptomatic heart failure with preserved ejection fraction (LVEF ≥50%). The intervention is designed to improve health status and other signs and symptoms of heart failure in patients with HFpEF. After enrollment, baseline data will be collected, and subjects will then have a pacemaker implanted. Following successful implant, and prior to pre-hospital discharge, subjects will be randomized 1:1 to one of two study groups. In the first group, subjects will have their pacemaker programmed to dual chamber pacing at a personalized cardiac pacing rate (treatment group) based on their LVEF and height. Subjects randomized to the second group will have their pacemaker programmed to receive ventricular pacing at a lower rate of 30 bpm to minimize interference with the subject's intrinsic heart rate (control group).

Subjects will complete 2-month, 6-month, and 12-month visits where data will be collected. At the 12-month visit, the second group (control group) will also be programmed to their personalized cardiac pacing rate. Subjects will complete 14-month, 18-month, and 24-month visits where data will be collected. Following the 24-month visit, additional long-term follow-up visits will occur annually until study completion. The estimated study duration is approximately 4.5 years representing an estimated 24-month enrollment period and 18-month follow-up period.

Enrollment

700 estimated patients

Sex

All

Ages

40+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Age ≥ 40 years

  2. Documented EF ≥50% within the preceding 12 months

  3. HFpEF defined as:

    1. Documented worsening HF episode (either HF hospitalization or documented urgent clinic visit for HF with intravenous diuretics) within 12-months prior to baseline visit OR

    2. Dyspnea on exertion and New York Heart Association (NYHA) ≥ class II symptoms AND AT LEAST ONE OF THE FOLLOWING CRITERIA:

      • Interstitial / pulmonary edema on prior chest imaging in the last year AND current loop diuretic use for heart failure

      • Elevated NT-proBNP in the last year defined as >400 pg/m for patients with no AF or paroxysmal AF, or >900 pg/ml for patients with ≥persistent AF

      • Mean pulmonary capillary wedge pressure (PCWP) ≥15 mm Hg or LVEDP ≥16 mm Hg at rest on cardiac catheterization OR pulmonary artery diastolic and wedge pressure (PADP) ≥15 mm Hg at rest on implantable monitor (e.g., CardioMEMs)

      • Echo criteria defined by ≥2 of:

        • LV wall thickness ≥ 12 mm
        • LV mass index (BSA indexed LVH): sex at birth male >115 g/m2, sex at birth female >95 g/m2
        • Relative wall thickness ≥0.42
        • E/e' ≥15 in sinus rhythm (or > 11 in the setting of atrial fibrillation) OR septal <7 cm/s or lateral e' <10cm/s
        • Tricuspid regurgitation (TR) velocity >2.8 m/s
        • Left atrial (LA) enlargement, defined by LA volume index >34 ml/m2
  4. Patient is on stable guideline indicated HF medical therapy (Class I recommendations) for at least 30 days

  5. Patient's average heart rate on baseline ambulatory electrocardiographic monitor is at least 5 bpm lower than their calculated personalized cardiac pacing rate (e.g. if a patient's personalized cardiac pacing rate is 70 bpm and their average heart rate on the ambulatory electrocardiographic monitor is less than or equal to 65 bpm the patient is eligible)

  6. Patient is willing and able to adhere to the protocol (e.g., patient is able to ambulate independently at baseline).

Exclusion criteria

  1. Improved or recovered EF (i.e., prior LVEF<50%)
  2. Patient has a previously implanted, currently implanted, or is intended to have implanted a cardiac implantable electronic device capable of delivering pacing (e.g., pacemaker, implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy (CRT))
  3. Current pregnancy (requirement for negative pregnancy test may vary by jurisdiction)
  4. Average heart rate <50 bpm or symptomatic bradycardia
  5. Acute coronary syndrome (including MI), cardiovascular surgery, or urgent percutaneous coronary intervention (PCI) within the 3 months prior to baseline visit or an elective PCI within 30 days prior to baseline visit.
  6. Current acute decompensated HF requiring intravenous diuretics, vasodilators and/or inotropic drugs.
  7. Severe obesity defined as BMI >45.
  8. Persistent, long-standing persistent, or permanent atrial fibrillation (AF) with an average heart rate <50 bpm or evidence of ventricular pauses exceeding 6 seconds
  9. Planned AF ablation
  10. Infiltrative cardiomyopathies (e.g., amyloidosis, sarcoidosis)
  11. Hypertrophic cardiomyopathies
  12. Uncontrolled hypertension as defined by BP >160/100 mmHg on two measurements ≥15 minutes apart
  13. End Stage Renal Disease (CKD 4 or greater)
  14. More than moderate valvular disease (e.g. exclude patients with moderate severe or severe valvular disease)
  15. Significant primary pulmonary disease on home oxygen
  16. Known contraindication for a pacemaker implant
  17. Advanced co-morbidity with life expectancy < 1 year
  18. Patients who are currently enrolled in a potentially confounding drug or device trial during the course of the study. Co-enrollment in concurrent trials is only allowed when documented pre-approval is obtained from the Medtronic Study Manager.
  19. Patient is a vulnerable adult (e.g. patient mentally incapable of giving consent).

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

700 participants in 2 patient groups

Personalized Pacing Therapy (Treatment Group)
Experimental group
Description:
The treatment group will receive a qualifying Medtronic dual chamber pacemaker limited to Astra XT or Azure XT and programmed to provide dual chamber pacing at a personalized cardiac pacing rate determined by patient height and baseline LVEF percentage.
Treatment:
Device: Personalized cardiac pacing
Control Group
No Intervention group
Description:
The control group will receive a qualifying Medtronic dual chamber pacemaker limited to Astra XT or Azure XT and programmed to provide ventricular pacing at a lower rate of 30 bpm. This is considered limited or backup pacing.