ClinicalTrials.Veeva

Menu

Endotracheal Intubation Using Three Laryngoscopes in Maternal Cardiac Arrest: a Manikin Simulation Study

H

Hanyang University Seoul Hospital

Status

Completed

Conditions

Cardiac Arrest

Treatments

Device: 15 degree left-lateral tilt wedges
Device: 30 degree left-lateral tilt wedges

Study type

Interventional

Funder types

Other

Identifiers

NCT02074072
HYI-14-004-1

Details and patient eligibility

About

European Resuscitation Council (ERC) Guidelines for Resuscitation 2010 emphasize high quality chest compressions .They propose minor changes for pregnant women: manual left deviation of the uterus or a left-lateral incline of 15-30to alleviate pressure on the inferior vena cava. We will examine the performance of the Glidescope (GVL), the Pentax-AWS Airwayscope(AWS) and Macintosh laryngoscope (McL) for airway management during chest compressions on 15 and 30 degree left-lateral tilt (15 &30 LLT) custom-made hard wedges.

Full description

Materials

  1. Sim Mom manikin (Laerdal, Stavanger, Norway)
  2. Stryker ST104-747(Transport stretcher®, 760 x 2110 mm, 228 kg, Stryker Co., Kalamazoo, Michigan, US)
  3. LUCAS Chest Compression System( LUCAS Chest Compression System, Physio-Control/Jolife AB)
  4. Backboard(450 ×600 ×10 mm, 3 kg Lifeline Plastic, Sung Shim Medical Co., Bucheon, Korea)

Enrollment

19 patients

Sex

All

Ages

18 to 60 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Experience of intubation > 50 times
  • Postgraduates year 1,2,3,4 and Emergency physicians in emergency department

Exclusion criteria

  • Wrist or Low back disease

Trial design

Primary purpose

Basic Science

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

19 participants in 3 patient groups

Direct laryngoscope
Experimental group
Description:
Macintosh laryngoscope
Treatment:
Device: 30 degree left-lateral tilt wedges
Device: 15 degree left-lateral tilt wedges
Videolaryngoscope-1
Experimental group
Description:
Glidescope
Treatment:
Device: 30 degree left-lateral tilt wedges
Device: 15 degree left-lateral tilt wedges
Videolaryngoscope-2
Experimental group
Description:
Airwayscope
Treatment:
Device: 30 degree left-lateral tilt wedges
Device: 15 degree left-lateral tilt wedges