Status
Conditions
Treatments
About
This study evaluates enhanced external counterpulsation as a non-pharmacological therapy for patients with severe and moderate ventilation disorders due to chronic lung diseases (chronic obstructive pulmonary disease, bronchial asthma and interstitial lung diseases). The study will include 80 patients with severe (30% < forced expiratory volume in 1 second < 49% or lung diffusion capacity < 40%) and moderate (50% < forced expiratory volume in 1 second < 59% or lung diffusion capacity 40-60%) ventilation disorders, who will be divided into 2 groups (the main group and the comparison group). In addition to optimal pharmacological therapy according to the current clinical guidelines of the Russian Ministry of Health, the main group will receive a course of enhanced external counterpulsation. The comparison group will receive only optimal pharmacological therapy (according to the current clinical guidelines of the Russian Ministry of Health). At the time of inclusion in the study and after 1 month, spirometry, bodyplethysmography, lung diffusion capacity, a 6-minute walk test and an assessment of quality of life according to the SF-36 questionnaire will be conducted.
Full description
Chronic lung diseases represent a significant medical and social burden, leading to reduced quality of life and high disability rates. Despite advances in pharmacotherapy, a subset of patients remains inadequately responsive to pharmacological treatments. Enhanced external counterpulsation, initially developed for cardiology, shows potential for improving pulmonary and respiratory muscle perfusion. This method based on counterpulsation by special cuffs on the legs in the phase of diastole of the heart. The operation of the enhanced external counterpulsation device is synchronized with the patient's electrocardiogram. In the phase of diastole of the heart, there is a rapid sequential inflation of air into the cuffs in the direction from the calves to the buttocks with subsequent compression of arterial vessels and retrograde direction of blood flow in the opposite direction - to the coronary vessels. The cuffs deflate before the next systole. However, its efficacy in pulmonology patients remains understudied. An open-label controlled trial involving 80 patients (n=40 main group, n=40 control group) age 35-74 years with severe (30% < forced expiratory volume in 1 second < 49% or lung diffusion capacity < 40%) and moderate (50% < forced expiratory volume in 1 second < 59% or lung diffusion capacity 40-60%) ventilation disorders, stable condition on optimal therapy (in accordance with the current clinical guidelines of the Russian Ministry of Health (extended-release beta2-agonists, extended-release m-cholinolytics, inhaled glucocorticosteroids, systemic glucocorticosteroids). The main group will receive 20 (5 days a week for 4 weeks) one-hour procedures (compression pressure 220-280 mmHg) of enhanced external counterpulsation (device: LUMENAIR EECP, Vasomedical Inc., USA, registration certificate №2018/6915 dated 15.03.2018) in addition to optimal pharmacological therapy. The comparison group will receive only optimal pharmacological therapy. At the time of inclusion in the study and after 1 month, spirometry (device MIR Spirolab I, bronchodilator 400 mcg of salbutamol - Salbutamol was registered on October 14, 2011, registration number: 001925), bodyplethysmography (Jager Master Screen Body), lung diffusion capacity (Jager Master Screen Body), a 6-minute walk test and an assessment of quality of life according to the SF-36 questionnaire will be conducted. Statistical data processing will be carried out using the StatTech program.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
80 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal